Project Configuration | 9
Bosch Motorsport
Manual_C_80
33 / 144
The conditional function works the following way:
The program always calculates the condition entered in the IF window and checks if the
condition is TRUE or FALSE.
If the condition entered in the IF window is TRUE, the program calculates the condition
entered in the THEN window. The returned value is the content of the new variable
(entered in “Name”).
If the condition entered in the IF window is FALSE, the program calculates the condition
entered in the OTHERWISE window. The returned value is the content of the new variable
(entered in “Name”).
The reset value is always set for the new variable (entered in “Name”):
– before the If-condition becomes TRUE for the first time after power-up
– when the If-condition changes state from FALSE to TRUE.
An example of a condition to set up the maximum front brake pressure is given on the
next page.
The conditional function is displayed in the C 80 math channel window.
Example: Setting up a condition for maximum front brake pressure
20
20
10
Max brake pressure of the variable ‘front p_br_front_mx’
Reset
value
is used
Hold
max.
value
Follow
max.
value
Reset
value
is used
Time
Time
Condition ‘p_br_front > 20’
Brake pressure front p_br_front
30
40
30
40
10
Brake pressure ‘front p_br_front’
Hold max.
value
Hold max.
value
Threshold
reached
– At power-up, the reset value (10) is used for ‘p_br_front_mx’.
Summary of Contents for C 80
Page 1: ...Data Logger and Sensor Interface C 80 Manual Version 1 0 04 08 2021 ...
Page 11: ...Mechanical Drawing 5 Bosch Motorsport Manual_C_80 11 144 5 Mechanical Drawing ...
Page 30: ...8 First Steps 30 144 Manual_C_80 Bosch Motorsport ...
Page 141: ...Bosch Motorsport Manual_C_80 141 144 ...
Page 142: ...142 144 Manual_C_80 Bosch Motorsport ...
Page 143: ...Bosch Motorsport Manual_C_80 143 144 ...
Page 144: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt www bosch motorsport com ...