background image

118

_58300000145664_ARA_EN_D.doc

 – 20.09.13 

Seite 2 von 12 

SAFETY 

1.1 

Safety instructions 

Risk of injury! 

Connect and operate the appliance only in 
accordance with the specifications on the rating 
plate.

Repairs may be carried out by a qualified electrician 
only!

The user may be put at considerable risk and injured 
by improper repairs!

Electric shock may occur if live components are 
touched inside the appliance!

Do not touch components in the appliance. Even the
modules can be live!

Before commencing repairs, ALWAYS disconnect 
the appliance from the power supply!

Components become hot during operation. Before 
commencing repairs, leave the appliance to cool 
down.

If tests have to be conducted while the appliance is 
live, ALWAYS use a residual-current-operated 
circuit-breaker!

The protective conductor connection must not 
exceed the standardised values! This is essential for 
personal safety and appliance function!

When repairs are complete, perform a test in 
accordance with VDE 0701/0702 or the 
corresponding national regulations!

DANGER 

1.2 

Repair instructions 

Comply with ESD information!

NEVER attempt repairs by randomly replacing 
components! 

ALWAYS proceed systematically and comply with
the technical documentation for the appliance!

As a rule, electronic boards are not repaired but 
are completely replaced with original spare parts. 
Exceptions are documented separately.

Following each repair, conduct  a performance 
test.

CAUTION 

D

Summary of Contents for BSG 8100

Page 1: ...nstructions 2 2 INSTALLATION 3 3 OPERATION 4 4 COMPONENTS 5 5 FUNCTIONS 6 6 REPAIR 7 6 1 Tools 7 6 2 Before disassembly 7 6 3 Disassembly 7 6 4 Assembly 9 6 5 After assembly 9 7 FAULT DIAGNOSTICS 10 7 1 General troubleshooting 10 7 2 Faulty resistor on motor electronics 10 7 3 Overheating protection is missing 11 7 4 Sealing of dustbox is not in correct position 11 8 TECHNICAL SPECIFICATIONS 12 Do...

Page 2: ...ncing repairs leave the appliance to cool down If tests have to be conducted while the appliance is live ALWAYS use a residual current operated circuit breaker The protective conductor connection must not exceed the standardised values This is essential for personal safety and appliance function When repairs are complete perform a test in accordance with VDE 0701 0702 or the corresponding national...

Page 3: ...118_58300000145664_ARA_EN_D doc 20 09 13 Seite 3 von 12 2 INSTALLATION ...

Page 4: ...118_58300000145664_ARA_EN_D doc 20 09 13 Seite 4 von 12 3 OPERATION ...

Page 5: ...118_58300000145664_ARA_EN_D doc 20 09 13 Seite 5 von 12 4 COMPONENTS ...

Page 6: ...118_58300000145664_ARA_EN_D doc 20 09 13 Seite 6 von 12 5 FUNCTIONS ...

Page 7: ...w driver T15 flat bladed screwdriver pliers 6 2 Before disassembly 1 Remove dust bag 2 Remove accessory 3 Remove exhaust HEPA filter 4 Remove motor protection filter 6 3 Disassembly 1 Open lid of the dust bag compartment 2 Remove 4 screws T15 arrows 3 Open lid of the exhaust filter 4 Remove 2 screws T15 arrows ...

Page 8: ...per housing part Pfeile and remove upper housing part 8 Remove upper housing part with cover 9 Remove adapter 1 from spindle 10 Unlock spindle carefully 2 and pull it carefully out of the potentiometer of the control electronics 3 11 Remove outer housing 12 Unlock inner housing with a flat bladed screwdriver arrows ...

Page 9: ...9 von 12 13 Remove inner housing You can now access motor electronics and cable reel 6 4 Assembly Proceed assembly in reverse order 6 5 After assembly 1 Insert dust bag 2 Insert accessory 3 Insert exhaust HEPA filter 4 Insert motor protection filter ...

Page 10: ...ectronics module Possible error defective by process of elimination if no faults are found with the motor or cable reel 7 2 Faulty resistor on motor electronics Check motor electronics at any kind of repair 7 2 1 Affected appliances BSG82480 15 from FD9006 to FD9008 7 2 2 Symptom Resistor R6 has not the specified value of 220 Ω The correct color coding of R6 with 220 Ω is 1st ring red 2nd ring red...

Page 11: ...ction mount 7 3 3 Solution The overheating protection is not missing Overheating protection has been omitted and is no longer required due to engineering changes Overheating protection is also no longer described in the user s manual 7 4 Sealing of dustbox is not in correct position 7 4 1 Affected appliances All bag bagless appliances with dustbox 670676 7 4 2 Symptom Sealing at the inlet of the d...

Page 12: ...118_58300000145664_ARA_EN_D doc 20 09 13 Seite 12 von 12 8 TECHNICAL SPECIFICATIONS ...