37
37
Operating Instructions
Specification
BC3200RA / BC3200RA5
Power Flue
Direct Ignition
200 -1,000 kPa
2.5 L/min.
615mm (Height) x 464mm (Width) x 240mm (Depth)
33 kg
1.9 L
R 3/4 (20mm)
R 3/4 (20mm)
R 3/4 (20mm)
230 / 240 VAC (50Hz)
126W Freeze Prevention 175W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Electric Leakage Prevention Device,
Lightning Protection Device (ZNR),
Overheat Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Anchoring Screws
Specifications
Specifications
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Primary Heat Exchanger
Safety Devices
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
NG
LP
25
°
C Rise
32 L/min.
2.5 - 42 L/min.
37 - 48
°
C (In 1
°
C intervals), 50
°
C (13 Options)
Maximum Performance
217 MJ/hr
217 MJ/hr
Minimum Performance
11 MJ/hr
11 MJ/hr
R 1/2 (15mm)
Water Outlet (Drain water)
Stainless Steel Sheeting, Stainless Steel Tubing
Secondary Heat Exchanger
Indoor / Outdoor, Wall Mounted
Approval certification number
1,600 kPa
Relief valve pressure setting
37 - 48
°
C (In 1
°
C intervals),
50, 55, 60, 65, 70, 75, 80
°
C (19 Options)
BC3200RA
BC3200RA5
AGA 6743 G