Bosch Water Heating

340 Mad River Park, Waitsfield, VT 05673

©

BBT

 NORTH AMERICA

Bosch Group

INDOOR

 INSTALLATION

FOR INDOOR INSTALLATION

REMOVE OUTDOOR VENT CAP AND 

 CUT PRESSURE SWITCH JUMP WIRE INSIDE UNIT THEN INSTALL

4" VENTING DIRECTLY ON FLUE OUTLET.

 

Use a UL listed wall terminator for cat 3 appliance

Combustion Air Supply

The water heater location must provide enough air for proper combustion. See the latest edition of ANSI Stan-

dard Z223.1 and any your local codes that should be applicable.

   DO NOT INSTALL DIRECTLY ON ANY COMBUSTIBLE SURFACE

In general these requirements specify that if the unit is installed in a confined space, there must be a permanent
air supply opening.

Minimum recommended Air supply to water heater

Water heater size

Outside air area

Inside air area

165,000 BTU

42 Sq. IN

165 Sq. IN

The area indicated is for one of two openings one at floor level and one at ceiling, so the total net free area would

be double the figures indicated.

Outside air supply: when combustion air is supplied directly through an outside wall, such as intake louvers
openings into the dwelling. Each opening should give a minimum free area of one square inch per 4000 BTUH
input of the total input rating of all appliances in the enclosed area.

Inside air supply, when combustion air is supplied from inside the building, each opening of the closet door
should have a minimum free area of one square inch per 1000 BTUH input of the total input rating of all appliance

in the enclosed area. These openings should never be less than 100 Sq. IN.

Venting Instructions.

This water heater must be vented in accordance with Venting ofcategory 3 appliance, of the latest edition of the
National Fuel Gas Code.

WARNING :

 Improper venting of this appliance can result in excessive levels of Carbon

 

Monoxide which

 

can

result in severe personal injury or death.

240FX

Summary of Contents for BBT NORTH AMERICA AquaStar 240FX

Page 1: ...osch Group OUTSIDE INSTALLATION Follow all local codes and in the absence of local codes follow the National Fuel Gas Code ANSI Z221 23 in USA or in Canada CAN CGA B149 1 or 2 Installation of Gas Burning Appliances Locate the water heater in an open unroofed area and maintain the following minimum clear ances from combustible and noncombustible materials Piping side 12 Front Maintenance space 24 F...

Page 2: ...G Do not have the flue terminal pointing toward any opening into a building Do not locate your heater in a pit or location where gas and water can accumulate WARNING Do not install the heater where water debris or flammable vapors may get into the flue terminal This may cause damage to the heater WARNING In the USA do not install the heater with the vent within 4 feet of any opening into a buildin...

Page 3: ... IN The area indicated is for one of two openings one at floor level and one at ceiling so the total net free area would be double the figures indicated Outside air supply when combustion air is supplied directly through an outside wall such as intake louvers openings into the dwelling Each opening should give a minimum free area of one square inch per 4000 BTUH input of the total input rating of ...

Page 4: ...EWALL VENTING When a horizontal vent run exceeds 5 ft the following criteria must be observed Attach a vertical pipe at least 2 high to the water heater outlet before the horizontal run Support the vent run at 3 ft intervals with overhead hanger Pitch up the vent run toward the vent terminal at a rate of 1 4 per foot Piping side Min 6 Front Maintenance space Min 4 24 suggested for maintenance spac...

Reviews: