TWH-TK-01

page 1 of 4

rev 01/06

Bosch Water Heating

340 Mad River Park, Waitsfield, VT 05673

©

BBT

 NORTH AMERICA

Bosch Group

OUTSIDE

  INSTALLATION

Follow all local codes and in the absence of local codes, follow the National Fuel Gas Code

ANSI Z221.23 in USA or in Canada CAN/CGA B149.1 or .2 Installation of Gas Burning

Appliances.

Locate the water heater in an open, unroofed area, and maintain the following minimum clear-
ances from combustible and noncombustible materials:

Piping side

12"

Front (Maintenance space)

24"

Floor

Non combustible base Min. 3" off the ground

Back of heater

1"

Non piping side

6"

Top of heater

36"

Do not install this water heater under an overhang, less than 3 feet from its top. The area under
an overhang must be open to three sides.

When installing the 240 FX  Water Heater on a placement stand, be sure to adjust the legs so

that it stands straight and securely. (Adjustable legs can be moved up to 1" )

240FX

INDOOR AND OUTDOOR

INSTALLATION INFORMATION

MODELS:

240FX

Summary of Contents for BBT NORTH AMERICA AquaStar 240FX

Page 1: ...osch Group OUTSIDE INSTALLATION Follow all local codes and in the absence of local codes follow the National Fuel Gas Code ANSI Z221 23 in USA or in Canada CAN CGA B149 1 or 2 Installation of Gas Burning Appliances Locate the water heater in an open unroofed area and maintain the following minimum clear ances from combustible and noncombustible materials Piping side 12 Front Maintenance space 24 F...

Page 2: ...G Do not have the flue terminal pointing toward any opening into a building Do not locate your heater in a pit or location where gas and water can accumulate WARNING Do not install the heater where water debris or flammable vapors may get into the flue terminal This may cause damage to the heater WARNING In the USA do not install the heater with the vent within 4 feet of any opening into a buildin...

Page 3: ... IN The area indicated is for one of two openings one at floor level and one at ceiling so the total net free area would be double the figures indicated Outside air supply when combustion air is supplied directly through an outside wall such as intake louvers openings into the dwelling Each opening should give a minimum free area of one square inch per 4000 BTUH input of the total input rating of ...

Page 4: ...EWALL VENTING When a horizontal vent run exceeds 5 ft the following criteria must be observed Attach a vertical pipe at least 2 high to the water heater outlet before the horizontal run Support the vent run at 3 ft intervals with overhead hanger Pitch up the vent run toward the vent terminal at a rate of 1 4 per foot Piping side Min 6 Front Maintenance space Min 4 24 suggested for maintenance spac...