en | Configuration
Conettix Ethernet Communication Module
2016.08 | 08 | F.01U.266.226
Installation and Operation Guide
Bosch Security Systems, Inc.
–
Module IP address, page 35
5.3.1
Web-based configuration log in and use
Notice!
If you cannot connect to the module, you might need to change the web browser
configuration so that it does not use a proxy server. Refer to the browser’s online help for
instructions on disabling proxy service.
Using web-based configuration (B426 Configuration Pages):
1.
Open an internet browser (Microsoft Internet Explorer 6 or higher, or Mozilla Firefox 3 or
higher), type in the B426’s IP address or hostname, and press [Enter]. (If Web and
Automation Security is enabled on the B426, you must type
https://
instead of
http://
).
The B426’s
Login
page opens.
Figure 5.1: B426 Login page
2.
Enter the password (default is B42V2) and click
Login
. The
Device Information
home
page opens. (Refer to Device Information (home) page , page 15.)
3.
Browse to the desired settings page.
4.
When you’ve finished making changes on the page, click
OK
.
Notice!
Before browsing to a new settings page, you must click
OK
to save edited values.
5.
Click
Save & Execute
to save and apply all changes to the device.
You should change your password from the default to secure module configuration. Change
the Web Access Password using the
Maintenance
page.