Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
© 2018 Bosch Security Systems, Inc.
F.01U.265.458 | 06 | 2018.05
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
Copyright
This document is the intellectual property of Bosch Security
Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and must be
treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to
the Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
8 | Point number examples
El-gr: Μεταβείτε στη διεύθυνση https://gr.boschsecurity.com/el/ για την
τεκμηρίωση σε αυτήν τη γλώσσα.
Es-es: Visite https://es.boschsecurity.com/es/ para obtener documentación en
este idioma.
Fr-fr: Accédez à l’adresse https://fr.boschsecurity.com/fr/ pour obtenir la
documentation dans cette langue.
Hu-hu: A honosított dokumentációt lásd a https://hu.boschsecurity.com/hu/
oldalon.
It-it: Andare a https://it.boschsecurity.com/it/ per la documentazione in questa
lingua.
Pl-pl: Dokumentacja w tym języku znajduje się w witrynie https://
pl.boschsecurity.com/pl/
Pt-br: Acesse http://pt.boschsecurity.com/pt/ para obter a documentação neste
idioma.
7 | Specifications
Dimensions
2.9 in x 5.0 in x 0.6 in
(73.5 mm x 127 mm x 15.25 mm)
Voltage
(operating)
12 V nominal
Current
(maximum)
150 mA (22 mA for digital s 16 mA
per energized relay)
Operating
temperature
+32°F to +122°F (0°C to +50°C)
Relative
humidity
5% to 93% at +90°C (+32°C) non-
condensing
Relay
outputs
Dry contacts rated for .001 to 1.0 A at 5 to
24 VDC (resistive load).
Terminal wire
size
12 AWG to 22 AWG (2 mm to 0.65 mm)
SDI2 wiring
Maximum distance - Wire size (Unshielded
wire only):
400 ft (122 m) - 22 AWG (0.65 mm)
1000 ft (305 m) - 18 AWG (1.02 mm)
Compatibility B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512/B5512E
B4512/B4512E
D9412GV4/D7412GV4/D7212GV4
(Refer to the control panel installation
document for number of supported
devices.)
6 | Certifications
Region
US
UL 365 - Police Station Connected Burglar Alarm
Units and Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 864 - Control Units and Accessories for Fire
Alarm Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System
Units
UL 1076 - Proprietary Burglar Alarm Units and
Systems
UL 1610 - Central-Station Burglar-Alarm Units
CSFM - California Office of The State Fire
Marshal
FCC Part 15 Class B
FDNY - Fire Department of New York
FM Approval 3010
Canada
CAN/ULC-S303 Local Burglar Alarm Units and
Systems
CAN/ULC-S304 Central and Monitoring Station
Burglar Alarm Units
ICES-003 - Information Technology Equipment
(ITE)
ULC/ORD-C1023 Household Burglar Alarm Sys-
tem Units
ULC/ORD-C1076 Proprietary Burglar Alarm
Units and Systems
When the tamper switch is on, the heartbeat LED stays OFF
for 3 second before showing the firmware version. The LED
flashes the major, minor, and micro digits of the firmware
version, with a 1 second pause after each digit.
For example, the version 1.4.3 shows as LED flashes:
[3 second pause]
*___****___***
[3 second pause, then
normal operation].
With a tamper switch:
1. Open the enclosure door.
2. Push and release the switch
5 | Show the firmware version
Without a tamper switch:
1. Quickly short the tamper pins.
2. Refer to the illustration below.
4 | LED descriptions
The module includes one heartbeat LED to indicate that
the module has power and to indicate the module’s current
state. Refer to the following table.
Flash Pattern Function
Flashes once
every 1 second
Normal operation state.
3 quick flashes
every 1 second
Communication error state: Indicates an
SDI2 communication error.
ON Steady
LED trouble state: Not powered (for
OFF Steady only), or some other trouble
condition.
OFF Steady
3.4 | Relay output wiring
Each output provides a NO and a NC output. The NO, C
(COMMON), and NC terminals are available in each terminal
or connection output position. The silkscreen on the edge
of the circuit board shows the function of each terminal and
the relay output number.
The middle terminal of each output position is the
COMMON and is labeled C. When the output is inactive,
the NC (Normally Closed) terminal has continuity with the
C terminal. When the output is active (energized), the NO
(Normally Opened) has continuity with the C terminal.
NOTICE!
Do not exceed relay contact ratings of 1.0 A, 24
VDC, resistive load.
For B308 address
01
the output numbers for the output devices
are 11 through 18:
Terminal no
1
2
3
4
5
6
7
8
Output no
11
12
13
14
15
16
17
18
For B308 address
11
the output numbers for the output devices
are 111 through 118:
Terminal no
1
2
3
4
5
6
7
8
Output no
111 112 113 114 115 116 117 118
en
Installation Guide
Octo-output Module
B308