6
en | Safety
AUTODOME IP starlight 5100i (In-ceiling)
2020-10 | 0.1 |
Installation Manual
Bosch Security Systems
- Follow proper safety precautions such as grounding for any outdoor device connected to this
unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, size of
grounding conductors, location of discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode.
Video loss -
Video loss is inherent to digital video recording; therefore, Bosch Security
Systems cannot be held liable for any damage that results from missing video information.
To minimize the risk of losing information, we recommend multiple, redundant recording
systems, and a procedure to back up all analog and digital information.
Always use Teflon tape and sealant on connector threads of any mount (sold separately by
Bosch or user-supplied).
1.5
Connection in applications
24 VAC power source:
This unit is intended to operate with a limited power source. The unit
is intended to operate at 24 VAC (if PoE+ is not available). User supplied wiring must be in
compliance with electrical codes (Class 2 power levels).
PoE:
Use only approved PoE+ devices. Power-over-Ethernet can be connected at the same
time as a 24 VAC power supply.
If auxiliary power (24 VAC) and PoE+ are applied simultaneously, the camera selects auxiliary
input and shuts off PoE+.