Figure 5.2: Selecting Transmitter Radio Frequency
Diagram
Radio Frequency
Switch Number 1
Switch Number 2
1
304 MHz (default)
OFF
OFF
2
303.825 MHz
OFF
ON
3
433.42 MHz
ON
OFF
Used for Factory Reset
ON
ON
Notice!
Remove the battery before setting the dip switches.
Use a white marker to indicate the configured RF on the back of the transmitter after setting
the dip switches.
Changes to the dip switches should be performed by administrators only.
Once the transmitter restarts after inserting the battery, the transmitter will emit a number of
beeping tones depending on the configured RF.
Radio Frequency
Number of Beeping Tones
303.825 MHz
1
304 MHz
2
433.42 MHz
3
Table 5.1: Number of Beeping Tones after Restarting
Factory Reset
Factory reset should be performed by administrators only. Set both dip switches 1 and 2 to
the ON position. While pressing the Test and Alarm buttons, the transmitter resets after
inserting the battery. If the reset is successful, there will be 3 slow consecutive beep tones
every 1 second. After a successful reset, select the transmitter RF by setting the dip switches
as described in Selecting Transmitter Radio Frequency, page 10. If the reset is unsuccessful,
there will be 2 slow consecutive beep tones every 1 second.
Refer to the following table which lists the values that are being set for the respective features
following the factory reset.
Feature
Value
Transmitter Type
Security
Man-Down
Disabled
5.2
ALLPLEX track Personnel Transmitter
Enabling and Disabling Features | en
11
Robert Bosch (SEA) Pte Ltd
Installation Manual
2014.03 | V1.0.0 | DL