18
en | Installation Manual
ARD-AYH12
| V 1.4 | 2010.04
Installation manual
Bosch Access Systems GmbH
1.4
TECHNICAL SPECIFICATIONS
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO)
or equivalent. Range also depends on electrical environment
and/or proximity to metal.
Suitable for Outdoor Use
1.5
MOUNTING DIAGRAM
Electrical Characteristics
Power Supply Type
Linear type recommended
Operating Voltage Range 5 - 16 VDC
Maximum Input Current
Standby: 35 mA
Read: 100 mA
Tamper Output
Open collector, active low, max
sink current 16 mA
Max Cable Distance to
Controller
500 ft. (150 meters)
Output modulation
26-bit Wiegand
Card read distance*
4.72 inch (12 cm)
RF Modulation
ASK
Regulatory Approvals
USA: UL 294 & FCC Part 15B
Europe: CE Listed
Environmental Characteristics
Operating Temp. Range
-25°F to 145°F (-31°C to 63°C )
Operating Humidity
0 to 95% (non condensing)
Dimensions
Height x Widht X Depth
4.33 x 2.95 x 0.59 inch
(109.91 x 74.91 x 15 mm)