22
en | Reader Functionality
ARD-AYCE65B
| V 1.1 | 2009.08
Installation manual
Bosch Sicherheitssysteme GmbH
If the PIN code is less than 5 digits, all the most significant
nibbles are filled with 0.
Example
: (EP) 0000 0000 0000 0000 AAAA BBBB (OP)
Where:
5.6
Changing the Programming Code
1.
Enter Programming Mode.
2.
Press "3" to enter Menu 3.
The Transmit LED will turn red.
3.
Enter the new 4 digit code you wish to set as the
Programming Code
4.
System returns to Transmit Mode
–
You will hear three beeps
–
The Program LED will turn off
–
The Transmit LED will turn red
B
=
Second key entered
E
=
Fifth key entered
C
=
Third key entered
EP
=
Even parity for first 12 bits
OP
=
Odd parity for last 12 bits
A
=
First key entered
B
=
Second key entered
NOTICE!
–
Programming Code can not be erased, i.e. the code 0000 is
invalid and will not erase the Programming Code.
–
The factory default 4-digit Programming Code is 1234.