The position you select on the temperature adjustment knob
will depend on the temperature of the incoming water (50°F
is average in the U.S.). In warm weather regions where the
incoming cold water is generally warmer, or during the hot
weather months in some other areas a midway setting on
the temperature adjustment knob would produce a
temperature rise of about 70°F, giving an output of
approximately 120°F.   At this setting,  if it is still necessary,
one could mix a small amount of cold water in a shower
and have a comfortable shower at about 3 gallons/minute.
During the colder months, or in cold climate areas, it might
be necessary to set the control to the maximum position,
all the way clockwise to the right.
Do not supply the AquaStar 125X with preheated water.
For this type of application, purchase a solar model 125B
LPS or 125B NGS.

Fig. 8 - Temperature Adjustment Knob

LIGHTING AND OPERATING INSTRUCTIONS

1. STOP! Read the safety information above on this label.
2. The gas valve must be shut off by putting the ON/OFF

switch to position “0”. Wait five (5) minutes to clear out
any gas. If you smell gas, STOP! Follow “B” in the safety
information above. If you do not smell gas, go to the
next step.

3. This water heater is equipped with a safety pilot burner

and an automatic ignition control system.

4. Set the ON/OFF switch (flip down cover plate on frontal

panel strip) marked 

I

/0 to the 

I

 position. In this position,

the water heater is ready to use.

5. If the red LED indicator light (visible through the

peephole in the front panel strip) is flashing, this is a
warning that the batteries are less than 1.2 Volts and
will need to be replaced within the next couple of weeks.
Plan to have two D type 1.5 volt long-life (Alkaline)
batteries available for replacement.

6. Turn the hot water faucet on the minimum flow rate

required to activate the heater. The automatic ignition
system first ignites the safety pilot burner which then
ignites the main burner in about 4 seconds.

7. The pilot flame will extinguish 10-30 seconds after the

burners come on. The burners will remain on until the
hot water tap is turned off.

NOTE: On a first time initial installation, existence of air in
the gas supply line and in the water line may cause some
ignition delay. In that case, repeatedly open and close the
hot water tap in order to restart the ignition process until
all the air has been purged.

TO TURN OFF GAS TO APPLIANCE

Turn off the manual lever on the gas supply line to the
heater and set the ON/OFF switch to the OFF ( 0 ) position.
See Fig 9.

SETTING THE WATER TEMPERATURE

The AquaStar 125 X LP and 125 X NG water heaters have a
gas control that modulates burner input in response to flow.
Its purpose is to ensure that the hot water temperature will
remain steady, although the water flow demand might vary
(down to 1/2 gal/minute). To adjust the temperature on your
AquaStar, turn on a hot water faucet to its maximum flow.
At the water heater, turn the large knob located beneath
the main gas control on the front of the heater all the way
to the right (clockwise).  See Fig 8. This will produce a
temperature rise of approximately 90°F at flow rates between
0.5 and 2.0 gallons per minute. Given that average incoming
water temperatures are 50°F, this heater will produce
approximately 140°F water at these flow rates. Turning the
dial all the way to the left (counterclockwise) will produce a
temperature rise of approximately 45°F for flow rates
between 1.1 and 3.7 gallons per minute. It is safest to select
a comfortable temperature and not have to mix in cold water.

TEMPERATURE
ADJUSTMENT KNOB

Align batteries as

shown

To operate the heater, set the ON/OFF switch to position 

I

.

The switch is located behind the flip down cover plate on
the front panel strip.
To shut down the gas to the heater, set the ON/OFF switch
to position 0

Temperature Adjustment Knob

If the LED light is flashing, prepare to
replace the batteries. Use two D cell
(1.5 volt) long life alkaline batteries.

G667_092

G667_090

G667_091

G661_004

Decrease temperature
and increase flow

Increases temperature

and decreases flow

Fig. 9 - Principles of Operation

Summary of Contents for AquaStar 125X LP

Page 1: ...onal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s inst...

Page 2: ... heating capacity of the heater Electronic Pilot Ignition Safety Flame Sensor at pilot burner not thermocouple On Off Switch to activate system LED indicator flashes before battery needs replacement AquaStar 125X LP and 125X NG Specifications Gas Input max 117 000 Btu hr min 28 000 Btu hr Water Connection 1 2 Thread fitting H x W x D 29 3 4 x 18 1 4 x 8 3 4 Vent 5 Gas Connection 1 2 NPT thread Min...

Page 3: ...STIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODEL 125X D870_072 MODEL 125 X TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 FLUE DIAMETER 5 Some local codes require 18 in garage installations ...

Page 4: ... underwater PROPER LOCATION FOR INSTALLING YOUR HEATER Carefully select the location of your new heater For your safety and for proper heater operation you must provide an abundant supply of combustion air and a proper venting installation Fig 0 Water heater drain plug The heater may still operate even when improperly vented It will however be less efficient and could eventually damage the heater ...

Page 5: ...n the right side panel of the cover Also each burner orifice is stamped with a number 79 for LPG and 120 for Natural Gas This product is not approved for manufactured homes mobile home recreational vehicles RV or boats Reference ANSI Z21 10 3 This product is neither designed or approved for outside installations COMBUSTION AIR REQUIREMENTS The AquaStar water heater holds cold water in its copper h...

Page 6: ...ARNING Failure TO INCREASETHE VENT SIZE TO SIX INCHESAND or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting asphyxiation and will void CSA Certification Fig 3 Flue Adaptor for High Altitude Canadian Installations 5 X 6 ADAPTOR USED ON HIGH ALTITUDE The incandescent particle tray shipped loose in the carton with the water ...

Page 7: ...f the serving gas supplier WARNING The heater must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0 5 psig The water heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 0 5 psig The...

Page 8: ...d between the PRV and the heater No reducing coupling or other restriction may be installed in the discharge line The discharge line must be installed such that it allows complete drainage of both the PRV and the line THREADEDASSEMBLY SWEATEDASSEMBLY The location of the PRV must be readily accessible for servicing or replacement and be mounted as close to the water heater as possible See Fig 7 To ...

Page 9: ...about 4 seconds 7 The pilot flame will extinguish 10 30 seconds after the burners come on The burners will remain on until the hot water tap is turned off NOTE On a first time initial installation existence of air in the gas supply line and in the water line may cause some ignition delay In that case repeatedly open and close the hot water tap in order to restart the ignition process until all the...

Page 10: ... the center core Yellow flames could be a sign of wrong size gas orifices or dirty burners or a blockage on the heat exchangers fins If some burners have yellow flames while others have good flames it is likely that dust lint or spider webs have partially clogged the burner venturis To clean the burners contact a gas service person Mineral Scale Build up The AquaStars heater when operated at lower...

Page 11: ...Water valve parts may be dirty or components damaged First check that venturi is free of dirt particles Water valve and component parts must be totally free of dirt In hard water areas mineral deposits can eventually 3 5 years in hard water areas corrode the water valve parts to a point where they will need replacing Any sign of moisture at the bleed hole is a sign that the water valve components ...

Page 12: ...ar 6 Parts in water flow valve are corroded so that the gas passage is not fully opening HOT WATER TEMPERATURE FLUCTUATES UNIT DEACTIVATED 1 Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot In such cases when mixing cold water at the tap the lower hot water pressure may be overpowered ...

Page 13: ...itch 12 Gas inlet gas pressure test nipple 13 LED 2 Cold water is mixing with the hot water between the AquaStar and the outlet See 4 under NO SPARKAT THE PILOT 3 Inlet water pressure is erratic due to inadequate supply water pressure or saturated pressure tank on well system Check the inlet water pressure On a private well raise minimum pressure setting to 30 psi Confirm that the pressure tank is...

Page 14: ...14 Fig 15 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Page 15: ... 708 504 021 15 Diaphragm switch LPG 8 708 504 049 16 Pilot burner assembly LPG 8 708 105 491 16 Pilot burner assembly NG 8 708 105 337 17 Electrode ignition group 8 718 107 067 18 Injector pilot NG 8 708 200 069 18 Injector pilot LPG 8 708 200 312 19 Pilot gas tube 8 700 707 349 20 Washer 8 700 103 173 21 Electronic control box 8 707 207 011 22 Battery box 8 700 505 062 23 Set of cables complete ...

Page 16: ...rigid Tubing 1 2 5 8 3 4 7 8 MAXIMUM LENGTH NOT RECOMMENDED 20 60 150 Flex tubing greatly reduces capacity and therefore is not recommended Minimum Vent Size and Height Minimum Diameter Minimum Height 5 inches 6 feet NOTE Vent size must not be restricted Installation must comply with national fuel gas code venting requirements for a 117 000 Btu Category I appliance and any applicable local codes W...

Reviews: