1 4 | TWH-G2-07 | 2400E, 2400EO, 635ES, 635ESO, 250SX, 250SXO
Service bulletin
Data subject to change without notice | Printed in the USA | 1.2007
Bosch Water Heating
BBT North America Corporation
Bosch Group
Bosch Water Heating
340 Mad River Park
Waits
fi
eld, VT 05673
Telephone 800-642-3111
Fax (802) 496-6924
Software version 3003 diagnostic codes
E
Entry/Exit into sub-modes
0P
Set-point temperature
1P
Inlet water temperature
2P
Outlet water temperature
3P
Water
fl
ow (liters/min)
4P
Water
fl
ow (gallons/min)
5P
Fan speed (Hz)
6P
Burner power (%)
7P
Maximum power (kW)
8P
PWM cycle (signal to fan)
9P
Appliance selection
1F
Most recent error/failure
2F
2
nd
most recent error
3F
3
rd
most recent error
4F
4
th
most recent error
5F
5
th
most recent error
6F
6
th
most recent error
7F
7
th
most recent error
8F
8
th
most recent error
9F
9
th
most recent error
10F
10
th
most recent error
Software version 3005 diagnostic codes
E
Entry/Exit into sub-modes
0d
Set-point temperature
1d
Inlet water temperature
2d
Outlet water temperature
3d
Water
fl
ow (gallons/min)
4d
Gas type (LP or NA)
5d
Fan speed (Hz)
6d
Burner power (%)
7d
Maximum power (kW)
8d
PWM cycle (signal to fan)
9d
Appliance selection
1F
Most recent error/failure
2F
2
nd
most recent error
3F
3
rd
most recent error
4F
4
th
most recent error
5F
5
th
most recent error
6F
6
th
most recent error
7F
7
th
most recent error
8F
8
th
most recent error
9F
9
th
most recent error
10F
10
th
most recent error