AMC2 4W | Installation manual

Technical Data | en

23

Bosch Sicherheitssysteme GmbH

F.01U.024.965 | V 0.1 | 2006.03

Power con-

sumption

Internal: 5 VA

Peripheral devices:

using the AMC PBC-60

up to 55 VA at 12V DC

constant load: 25 VA

peak load: 30 VA

Connectors

Pluggable screw connectors

Protection 

Class

IP30

Environment 

temperature

0°C to 45°C

Humidity

Up to 95%, without condensation

Housing mate-

rial

Bottom: PPO (UL 94 V-0)

Top: Polycarbonate (UL 94 V-0)

Dimensions

(W/H/D) 225mm x 88mm x 60mm (8.9" x 

3.5" x 2.4")

Weight: app. 0,48 kg (0.9 pounds)

Summary of Contents for AMC2 4W

Page 1: ...AMC2 4W APC AMC2 4W APC AMC2 4WCF APC AMC2 4WUS en Installation manual ...

Page 2: ......

Page 3: ...rranties or limitation of liability for incidental or consequen tial damages so the above limitation or exclusion might not apply to you Bosch Security Systems retains all rights not expressly granted Nothing in this license constitutes a waiver of Bosch s rights under the U S Copyright laws or any other federal or state law If you have any questions concerning this license please write to Bosch A...

Page 4: ... System Overview21 4 Technical Data22 5 Installing26 5 1 Mounting26 5 2 Demounting27 5 3 Opening the AMC2 4W Case28 5 4 Cabling28 5 5 Connecting Power Supply31 5 6 RS 485 Host Interface33 5 6 1 RS 485 Two Wire Connection35 5 6 2 RS 485 Four Wire Connection36 5 6 3 DIL Switch Address Selector37 5 7 RS 232 Host Interface39 5 8 Ethernet Interface41 5 9 RS 485 Extension Module Bus42 5 10 Wiegand Inter...

Page 5: ...AMC2 4W Installation manual Table of Contents en 5 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 7 2 Legend58 8 Index59 ...

Page 6: ...6 en Table of Contents AMC2 4W Installation manual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH ...

Page 7: ...er to keep in mind These appear different from the rest of the text as fol lows 1 2 Internet If you are interested in further information on this product or information on other products please refer to our website at http www bosch security systems com CAUTION or WARNING These warn the operator that damage to the program or equip ment might occur i NOTE Important Notes must be followed for succes...

Page 8: ...Are Interested in Your Opinion We constantly try to improve the quality of our products and our manuals Should you have any suggestions for improve ment please send us your comments Bosch Security Systems Adenauerstr 20 A3 D 52146 Würselen Germany Tel 49 24 05 60 05 0 Fax 49 24 05 60 05 29 Email info service de bosch com ...

Page 9: ...s injury to persons and damage to the unit Mount the unit according to the manufacturer s instructions 5 Cleaning Disconnect the unit from power before cleaning Follow any instructions provided with the unit Generally using a damp cloth for cleaning is sufficient Do not use liq uid cleaners or aerosol cleaners 6 Service Do not attempt to service this unit by yourself Opening or removing covers may...

Page 10: ...ly 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer For units intended to operate from battery power refer to the operating instructions For units intended to operate with External Power Supplies use only the recommended approved power supplies For units intended to operate with a limited po...

Page 11: ... the plug fully into the out let try reversing the plug If the plug still fails to fit con tact an electrician to arrange replacement of the obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 wire grounding plug a plug with a third pin for grounding This safety feature allows the plug to fit into a grounding power outlet only If un...

Page 12: ...residental installation This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com munications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can...

Page 13: ...of damaging equipment Always switch off power of the AMC2 4W before mod ifying the installation Do not connect or disconnect plug connectors data cables or screw connectors while power is on Health and Safety Installation of the AMC2 4W must comply with any local fire health and safety regulations A secured door that may be part of an escape route from an area must be installed with A fail safe lo...

Page 14: ...curity Systems salesperson The shipping car ton is the safest transport container for the unit Store it and the other packaging material for future use If the unit has to be sent back use the original packaging CAUTION You must ground the AMC2 4W Disconnect both AC and bat tery power supply before working on the controller Warning Risk of damage Protect the hardware from electrostatic discharge by...

Page 15: ...tion is stored in a battery buffered on board memory and a Compact Flash CF memory card This guarantees autonomous access decisions and complete access registrations even if the management host system is offline The built in compact flash adapter provides adequate storage capability for cardholders and events The AMC2 4W electronic is completely covered by a plastic housing The LC Display provides...

Page 16: ... can be used to activate lock mechanisms if access is granted or activate an external alarm system if an intrusion or system alert is detected If the eight input and output on board are not enough to configure the system up to three additional extensions AMC 8I 8O or AMC 16I 16O can be connected The extensions offer 8 or 16 additional inputs and outputs The setup procedure for an AMC2 4W is very s...

Page 17: ...ll be replaced by qualified per sonnel every ten years or if indicated by an appropriate event 4 Reset push button available by using the srew driver 5 LC Display 6 Push button to select the display view available by using the push button on the top of the housing 7 Jumper Potential equalization between different mass sys tems and protective earth shield 8 Jumper interface selector RS 485 Host con...

Page 18: ...le 10 100 Mbit s Ethernet interface Fig 3 4 Overview Interfaces 13 RS 485 extension module bus Pluggable screw connector 14 External tamper contact Pluggable screw connector 15 Power supply Pluggable screw connector 16 Wiegand interface for card readers Pluggable screw con nector 17 Analog input Pluggable screw connector 18 Relay Output Pluggable screw connector I IV Channel 1 4 ...

Page 19: ...bH F 01U 024 965 V 0 1 2006 03 Fig 3 5 Jumper at the bottom side 19 Jumper Selector for either potential free relay output or powered by AMC2 4W internal power supply wet dry con tacts 20 Jumper Potential equalization between different mass systems and protective earth shield ...

Page 20: ...ipheral input devices via Wiegand interface Eight relay outputs potential free or with internal power supply Eight analog inputs with internal power supply Battery buffered SRAM and real time clock RTC Pluggable Compact Flash from 64 MB to 1024 MB LC Display Transfer rate host interface RS 485 38 4 kBit s Self controlling transfer receive switching Power supply for internal electronics 10V 30VDC m...

Page 21: ...anagement host system and different peripheral devices By default a management host system is connected via Ethernet A management host connection via RS 485 or RS 232 is also pos sible Fig 3 6 System overview In RS 485 mode up to eight access controllers AMC2 4W can be combined on one party line Via Wiegand interfaces up to four peripheral devices can be connected to each AMC2 4W ...

Page 22: ... RTC Host address selectable via DIP sliding switch or software Host interface RS 485 2 wire or 4 wire Transfer rate 38 4 kBit s No parity 8 Bit 1 Stopbit RS 232 Ethernet four Wiegand interfaces for card read ers Eight relay outputs Maximum switching power 60VA Maximum switching voltage 30V AC DC Maximum switching current 2A eight analog inputs with sabotage mon itoring Tamper contact for enclosur...

Page 23: ...sing the AMC PBC 60 up to 55 VA at 12V DC constant load 25 VA peak load 30 VA Connectors Pluggable screw connectors Protection Class IP30 Environment temperature 0 C to 45 C Humidity Up to 95 without condensation Housing mate rial Bottom PPO UL 94 V 0 Top Polycarbonate UL 94 V 0 Dimensions W H D 225mm x 88mm x 60mm 8 9 x 3 5 x 2 4 Weight app 0 48 kg 0 9 pounds ...

Page 24: ...age drop shall not exceed 2V Example Length 50m 165 ft U 12V I 2A maximum VDrop 2V i e RAWG18 acc specs or 20 948 VDrop 20 948 2 1V VDrop 2 1V Critical condition Install the power supply closer to the controller Conductor data relay outputs Use AWG18 conductors Please calculate your voltage drop see above by checking conductor specifica tions for characteristic resistance values Conductor data ana...

Page 25: ...01U 024 965 V 0 1 2006 03 Conductor data RS 485 slave Use AWG22 conductors Please calculate your voltage drop see above by checking conductor specifica tions for characteristic resistance values CAUTION The voltage drop at the different cables add up Their sum shall be less than 2V ...

Page 26: ... 5 Installing 5 1 Mounting The AMC2 4W can be attached on a standard 35 mm mounting rail via a snap in mechanism Attach the AMC 4W into the upper edge of the mounting rail then push down the AMC2 4W and snap it onto the rail by pushing it towards the back Fig 5 1 Mounting the AMC2 4W on a mounting rail ...

Page 27: ... 0 1 2006 03 5 2 Demounting Push down the AMC2 4W until it snaps out of the mounting rail Pull the lower end of the AMC2 4W from the mounting rail Fig 5 2 Demounting the AMC2 4W from a mounting rail i NOTE To remove the AMC2 4W from a mounting rail first remove all pluggable screw connectors ...

Page 28: ... driver After that the cover can be moved to bottom Fig 5 3 Opening the AMC2 4W case 5 4 Cabling i NOTE To open the AMC2 4W first remove all pluggable screw con nectors at least the host connection CAUTION The cables used in the AMC2 4W access control system are not prone to electrical interference However you should avoid routing cables close to heavy load switching cables and equip ment If this ...

Page 29: ...of the shield preferably the source end Connecting both ends of a shield will result in ground loops It is recommended that the unconnected end of the shield be insulated to prevent accidental connection The AMC2 4W enables you to set up a central ground or shield ing point simply by setting a couple of jumpers Set these jumpers only if ground or shield is not connected otherwise Fig 5 4 Location ...

Page 30: ...ductor of the RS 485 host interface Jumper JP1 should be set at every AMC2 4W Setting jumper JP2 connects the internal ground of the AMC2 4W to the shield of the RS 485 host interface Set Jumper JP2 only at the first AMC2 4W of a party line The host system must not connect cable shield and protective ground If the AMC2 4W is set to RS 232 mode Jumper JP2 must be set Fig 5 5 Location of ground jump...

Page 31: ...Location of the power supply connector An external power supply 10 30V DC must be connected for internal electronics at pin 1 positive and pin 3 negative of the pluggable screw connector An additional power supply 12V DC for peripheral devices i e card readers and door openers must be connected at pin 6 positive and pin 7 negative i NOTE A complete connection diagram is shown in chapter Section 7 ...

Page 32: ...tened If an uninterruptible power supply UPS is used the relay out put for power good signals from the UPS is connected to the following pins pin 4 and 7 for power good AC pin 5 and 7 for power good Battery pin 6 and 7 for power good DC Otherwise these pins must be short circuited WARNING Risk of Damage Power supply for external devices is 12V DC only Applying higher voltages may cause hazards to ...

Page 33: ...n 33 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 5 6 RS 485 Host Interface An RS 485 host system can consist of up to eight AMC2 4W con trollers connected via 2 or 4 wire connection Fig 5 7 Configuration of a RS 485 host system ...

Page 34: ... the host computer Peripheral devices are AMC2 4W which are connected to the host computer Maximum cable length of a bus line must not exceed 1200m or 4000ft The cable length of branch lines must not exceed 100m or 300ft Any bus line conductor connects up to eight AMC2 4W The maximum number of devices must not be exceeded For longer bus lines connect the AMC2 4W to multiple AMC MUX EXT with the ho...

Page 35: ... 5 8 RS 485 host interface 5 6 1 RS 485 Two Wire Connection Fig 5 9 Connection scheme of a RS 485 two wire connection Fig 5 10 Settings for RS 485 two wire connections i NOTE A complete connection diagram of the RS 485 host interface is shown in chapter Section 7 1 Connecting Diagrams of this docu mentation ...

Page 36: ...teme GmbH 5 6 2 RS 485 Four Wire Connection Fig 5 11 Connection scheme of an RS 485 four wire connection Fig 5 12 Settings for RS 485 four wire connection i NOTE A complete connection diagram of the RS 485 host interface is shown in chapter Section 7 1 Connecting Diagrams of this docu mentation ...

Page 37: ... different protocols SDEB and BPA according to DIN6619 Switch 6 sets the connection to the host system to either RS 232 or RS 485 Fig 5 13 Location of the RS 485 address selector i NOTE Using Ethernet connection it is recommended to set switch 1 to ON delivery status Using RS 232 connection the address must be set which is con figured in the Device Editor Therefore this is a point to point connect...

Page 38: ...witches 1 2 3 4 none OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON Table 5 1 Setting the RS 485 address with the DIP swich Mode DIP Switches 5 6 ON SDEB RS 232 OFF BPA RS 485 Table 5 2 Protocol and connection settings ...

Page 39: ...U 024 965 V 0 1 2006 03 5 7 RS 232 Host Interface The AMC2 4W offers an RS 232 serial interface to connect a host computer or serial modem Fig 5 14 Location of the RS 232 serial interface CAUTION Cable length between two RS 232 COM serial interfaces must not exceed 15 meters 45 ft ...

Page 40: ... 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH Fig 5 15 Connection scheme of the RS 232 interface i NOTE A complete connection diagram of the RS 232 host interface is shown in chapter Section 7 1 Connecting Diagrams of this docu mentation ...

Page 41: ... local area network or host computer Fig 5 16 Location of the Ethernet interface CAUTION Use either a CAT5 crossover cable to connect the AMC2 4W directly to a computer s network interface or a standard CAT5 patch cable to connect the AMC2 4W to a network hub or net work switch i NOTE A complete connection diagram of the Ethernet host interface is shown in chapter Section 7 1 Connecting Diagrams o...

Page 42: ... AMC2 4W with additional I O modules AMC 8I 8O or AMC 16I 16O Up to three expansion modules can be connected to provide addi tional in and outputs for example for elevator control Fig 5 17 Location of the RS 485 extension module bus i NOTE A complete connection diagram of the RS 485 extension mod ule bus is shown in chapter Section 7 1 Connecting Diagrams of this documentation ...

Page 43: ...d interfaces to integrate up to four card readers with Wiegand compatible interfaces Each interface is connected via a 10 pin pluggable screw connector S2 S7 S14 and S19 Fig 5 18 Location of the Wiegand interfaces for external devices i NOTE A complete connection diagram of the Wiegand interface is shown in chapter Section 7 1 Connecting Diagrams of this docu mentation ...

Page 44: ...C2 4W has eight form C relay outputs The outputs will be connected to the 3 pin pluggable screw connectors S5 S6 S10 S11 S17 S18 S22 and S23 Fig 5 19 Location of the relay output connectors Each relay output can operate in wet mode using the AMC2 4W s internal 12V DC power supply for external devices or dry mode with potential free contacts for externally powered sys tems ...

Page 45: ...age 30 V DC and maximum switching cur rent 2 A Risk of Damage Do not connect externally powered devices in wet mode This can damage the AMC2 4W Risk of Damage Do not exceed switching specifications of the relay Using exceeding voltage or current on relay contacts in either mode can damage the AMC W i NOTE A complete connection diagram of the relay output connectors is shown in chapter Section 7 1 ...

Page 46: ...ual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH Each relay output has a separate jumper setting on the bottom side of the lower circuit board to activate wet D2 or dry D1 mode Fig 5 21 Location of relay output jumpers bottom side ...

Page 47: ...for example for poten tial free lock mechanisms or to detect if a lock is closed or open The inputs will be connected to the 2 pin pluggable screw connectors S3 S4 S8 S9 S15 S16 S20 and S21 Fig 5 22 Location of the analog input connectors The AMC2 4W can also detect the wiring conditions short cir cuit and broken and initiate an alarm if the appropriate devices are connected ...

Page 48: ...P 4 Short circuit RS RP 0 The resistor values can vary and depend on the used lock system wire resistance negligible Default values are RS 2 2 k RP 4 7 k Fig 5 23 Operating modes of a lock using the analog input device i NOTE A complete connection diagram of the analog input devices is shown in chapter Section 7 1 Connecting Diagrams of this docu mentation ...

Page 49: ...rized access and pre vent the AMC2 4W from tampering with sensitive data the AMC2 4W offers an additional interface to connect external tamper contacts This interface is a potential free 2 pin plugga ble screw connector marked with T If not using the tamper contact short circuit the contacts with a wire connection Fig 5 24 Location of the tamper protection contact ...

Page 50: ...C2 4W The LC Display delivers information about the AMC2 4W status Push the Dialog button to switch between different modes Fig 6 1 Location of the Dialog button The display mode which has been set remains until the next operation of the Dialog button The order of the display pages is determined and follows the scheme shown in the table below ...

Page 51: ...O Display of the digital contacts setted input signals will be shown with an extension above output signal with an extension below 3a Dig I1 If there are I O Boards con nected the signals will be shown on separate pages 3b Dig I2 3c Dig I3 4 MAC 0010174C8A0C MAC address 5 N AMC 1234 5678 Network name of the AMC 6 I 192 168 10 18 IP address of the AMC 7 H 0 0 0 0 IP address of the host computer 8 D...

Page 52: ...as shown in the figure below 2 Push the reset button for at least three seconds 3 The AMC2 4W will be reset and reboots You are back in the download program 4 Now it is possible to reconfigure the AMC2 4W from the beginning 5 If the problem still arises please call your local service Resetting the network configurations 1 Reset the AMC as described above in download program 2 Open the upper case o...

Page 53: ...4W Installation manual Operating en 53 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 Fig 6 2 Restarting the AMC2 4W with the provided screw driver Fig 6 3 Resetting the AMC2 4W to delivery state ...

Page 54: ...54 en Appendix AMC2 4W Installation manual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH 7 Appendix 7 1 Connecting Diagrams Fig 7 1 Connectors on upper PCB Fig 7 2 RS 485 host on upper PCB ...

Page 55: ...AMC2 4W Installation manual Appendix en 55 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 Fig 7 3 Connecting diagram of the RS 232 serial interface Fig 7 4 Ethernet Network socket RJ45 ...

Page 56: ...56 en Appendix AMC2 4W Installation manual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH Fig 7 5 Connector blocks of the AMC2 4W ...

Page 57: ...AMC2 4W Installation manual Appendix en 57 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 Fig 7 6 Power supply Fig 7 7 Wiegand interface Fig 7 8 Analog input Fig 7 9 Relay output ...

Page 58: ...Appendix AMC2 4W Installation manual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH Fig 7 10 Slave interface Fig 7 11 External tamper contact 7 2 Legend Twisted pair connection Transmitter Receiver ...

Page 59: ...e 23 Equipment Configuration 17 Ethernet Interface 41 G Grounding 29 H Hardware 22 Housing material 23 Humidity 23 I Installing the AMC 4 26 Internet 7 L Legend 58 O Opening the AMC 4 Case 28 Operating the AMC 4 50 P Performance Characteristics 20 Power consumption 23 Power Supply 31 Power supply 22 Protection Class 23 R Relay Outputs 44 Resetting the AMC 4 52 RS232 Host Interface 39 RS485 Extensi...

Page 60: ...60 en Index AMC2 4W Installation manual F 01U 024 965 V 0 1 2006 03 Bosch Sicherheitssysteme GmbH U Used Symbols 7 W Wiegand Interface 43 ...

Page 61: ...AMC2 4W Installation manual Index en 61 Bosch Sicherheitssysteme GmbH F 01U 024 965 V 0 1 2006 03 ...

Page 62: ...Bosch Sicherheitssysteme GmbH Robert Koch Straße 100 D 85521 Ottobrunn Germany Telefon 089 6290 0 Fax 089 6290 1020 www bosch securitysystems com Bosch Sicherheitssysteme GmbH 2006 ...

Reviews: