Output Time
0523 - 525
000
VDS-A
EN=180
Output 3
Output Event Type
0526 - 0527
05
VDS-A
EN=5
Output Area / Zone
0528 - 0529
00
Output Mode
0530
0
VDS-A EN=0
Output Time
0531 - 0533
180
VDS-A
EN=180
Output 4
Output Event Type
0534 - 0535
07
VDS-A
EN=5
Output Area / Zone
0536 - 0537
00
Output Mode
0538
0
VDS-A EN=0
Output Time
0539 - 0541
180
VDS-A
EN=180
Notice!
When the zone activating alarm is programmed as silent alarm, keypad and audible alarm have
no output.
For the corresponding value ranges of output event type, output mode and output time as well
as the relationship between output event type and Output in area see The Value Ranges of
Output Programming Options, page 39
The Value Ranges of Output Programming Options
Output Event Type
Description
Output Area / Zone
Output
Event
0
Not Used
No
1
System Disarmed
0 = All Areas
1 – 16 = Areas 1 - 16
2
System Armed
3
System Alarm
0 = Any Area,
1 - 16 = Areas 1 - 16
4
System Alarm (audile and silent)
5
External AWAY Siren
6
External STAY Siren
7
Internal Siren
8
Internal Siren with tamper
9
Entry/Exit Delay Warning
1 - 16 = Areas 1 - 16
10
Telephone Line Fault
11
AC Power Supply Fault
12
Low Battery
13
Tamper
0 = Any Area,
AMAX panel 4000 / AMAX panel 4000