Errors – Causes and Corrective Measures
Cause
Corrective measure
AL 1815 CV: Battery charge indicator
(3)
is continuously lit
1830 AL 1880 CV: Battery charge indicator
(3)
is continuously lit. Red battery
charge indicator
(2)
is flashing.
Charging not possible
The battery is not connected (correctly)
Connect battery to charger correctly
Battery contacts are dirty
Clean battery contacts; e.g. by connecting
and disconnecting the battery several
times. Replace battery if necessary
Battery defective
Replace battery
Green battery charge indicator(3)/red battery charge indicator
(2)
is not illumin-
ated
Mains plug of the charger is not (correctly)
plugged in
Insert the mains plug into the mains socket
(completely)
Socket outlet, mains cable or charger de-
fective
Check mains voltage, have charger
checked if necessary by an authorised
after-sales service centre for Bosch power
tools
Practical advice
When the charger is used continuously, or for several consecutive charge cycles without
interruption, the charger may heat up. This is, however, harmless and does not indicate
that the charger has a technical defect.
A significantly reduced operating time after charging indicates that the battery has de-
teriorated and must be replaced.
Battery Cooling (Active Air Cooling) (AL 1880 CV)
The fan control unit integrated into the charger monitors the temperature of the inserted
battery. As soon as the battery temperature is above approx. 0 °C, the battery will be
cooled by a fan. The fan generates a ventilation sound when switched on.
If the fan does not run, it is defective or the battery temperature is < 0 °C. This can in-
crease the charging time.
English |
17
Bosch Power Tools
1 609 92A 4BK | (15.05.2018)