AEGIS SUPERLED INSTALLATION INSTRUCTIONS

 

 

1.  

Description 

2.  

Specification 

3.  

Installation 

4. Safety 
5. Dimensions 
6. Remote 

Switching 

7. Trouble 

Shooting 

8. Certification

 

 
 

DIAGRAMS 

 

Fig 1.   Installing the AEGIS SuperLED illuminator 
Fig 2.   AEGIS SuperLED rear side view 
Fig 3.   AEGIS SuperLED right side view 
Fig 4.   Telemetry Input pin layout 
Fig 5.   Camera Day/Night Output pin layout 
Fig 6.   Adjustment of the photocell sensitivity 
Fig 7.   Adjustment of the output power 
Fig 8.   Dimensions  

 
 

BOX CONTAINS 

 

  

1 x

  

AEGIS SuperLED

 

illuminator

 

   

1 x

  

AEGIS SuperLED

 

bracket

 

 1 

x

  

AEGIS SuperLED

 

Installation Instructions (this booklet) 

Whilst every effort has been made to ensure that all information contained in this document is 
correct at the time of publication, due to continuous product development Bosch reserves the right 
to change information herein without prior notice   

Summary of Contents for Aegis Superled

Page 1: ...AEGIS SUPERLED INSTALLATION INSTRUCTIONS INFRARED WHITE LIGHT ILLUMINATOR ...

Page 2: ...2 ...

Page 3: ... layout Fig 5 Camera Day Night Output pin layout Fig 6 Adjustment of the photocell sensitivity Fig 7 Adjustment of the output power Fig 8 Dimensions BOX CONTAINS 1 x AEGIS SuperLED illuminator 1 x AEGIS SuperLED bracket 1 x AEGIS SuperLED Installation Instructions this booklet Whilst every effort has been made to ensure that all information contained in this document is correct at the time of publ...

Page 4: ...me images Energy efficient low voltage operation for quick and easy installation High efficiency surface mount LEDs deliver improved thermal management long life and low cost of ownership Semi covert covert and white light versions Easy integration with day night cameras with relay contacts COM NC NO that indicate whether the photocell has activated the illuminator Telemetry input connection addit...

Page 5: ...tage 12 24 Volt DC or 24 Volt AC 15 50 60 Hz NOTE for American market Conforming Underwriters Laboratories UL 2108 standard regulations use a Class 2 Power Supply Unit Temp range 40 C 40 F to 50 C 122 F max on full power Environmental IP67 suitable for indoor outdoor use Construction Robust aluminum extrusion with acrylic front window Dimensions 303mm x 239mm x 110mm 11 9 x 9 4 x 4 4 including mou...

Page 6: ...cated 1 meter cable to synchronize multiple illuminators Brackets U mount bracket included Please check the Bosch website for other available mounting options Lens Beam pattern The illuminator should be matched to the scene and the camera lens focal length Before installation ensure that the illuminator has been correctly specified to support the CCTV system The system planning must take into acco...

Page 7: ...BD 940nm 20 120m 395ft 42m 135ft SLED30 9BD 940nm 30 90m 295ft 47m 154ft SLED60 9BD 940nm 60 65m 210ft 75m 245ft SLED95 9BD 940nm 95 45m 145ft 100m 330ft SLED120 9BD 940nm 120 30m 100ft 110m 360ft SLED10 WBD White Light 10 85 m 275 ft 15 m 50 ft SLED20 WBD White Light 20 55 m 180 ft 20 m 65 ft SLED30 WBD White Light 30 50 m 165 ft 25 m 85 ft SLED60 WBD White Light 60 35 m 115 ft 40 m 130 ft SLED95...

Page 8: ...amp to 12 24 Volt DC or 24 Volt AC 15 50 60 Hz 3 Commission the mains supply camera and monitoring control equipment 4 Adjust the pan of the illuminator to match the camera field of view 5 Adjust the vertical alignment by loosening the side bolts one on each side of the main body to maximize the results 6 Tilt the lamp downwards until the near part of required field of view is saturated with light...

Page 9: ... Night Camera Switching Output Pressure Equalisation Vent Power Input 12 24 Volt DC or 24 Volt AC 15 50 60 Hz Fig 2 AEGIS SuperLED rear side view Fig 3 AEGIS SuperLED right side view Power Adjustment Photocell Sensitivity Adjustment ...

Page 10: ...10 Telemetry Input Connection Fig 4 Telemetry Input pin layout Camera Day Night Switching Output Connection Fig 5 Camera Day Night Output pin layout ...

Page 11: ...ew The potentiometer is factory set at the maximum calibration point fully clockwise To decrease the power turn the potentiometer counter clockwise using a thin maximum 2 5mm or 0 1inch diameter flathead screwdriver Hi Power reduction Fig 7 Adjustment of the output power Fig 6 Adjustment of the photocell sensitivity Turn clockwise to increase photocell sensitivity Photocell will switch lamp ON ear...

Page 12: ...cation for 850nm models The product is tested and compliant to IEC EN 60825 1 2001 under normal operating conditions and is classified as a Class 3R LED product The measured output under the thermal hazard test Class 1 3R was 36 9mW peak at 850nm wavelength The following notification label is placed on the side of the product Class 1M notification for 940nm models The product is tested and complia...

Page 13: ...d and compliant to IEC EN 60825 1 2001 under normal operating conditions and is classified as a Class 2 LED product The measured output was 10mW peak at 590nm wavelength The following notification label is placed on the side of the product 5 DIMENSIONS Fig 8 Dimensions ...

Page 14: ...iple illuminators Multiple illuminators can be linked for synchronous illuminator switching Use link cable UFLED CL 1M between the DAY NIGHT CAMERA output and the TELEMETRY input as shown in the diagram below Illuminator leading The DAY NIGHT CAMERA output may be used to switch the camera between the Day and Night mode Use interface cable UFLED CI 5M UFLED CI 5M Camera Illuminator UFLED CI 5M Illu...

Page 15: ...8 UL2108 Laser Eye Safety IEC EN60825 1 EMC Radiated and Conducted Emissions EN55022 1998 ICES 003 Issue 4 2004 Immunity EN50130 4 1995 FCC CFR 47 2007 PART 15 107 15 109 CLASS B LIMIT IP Ingress Protection IP67 in accordance with BS EN60529 1992 WEEE Waste Electrical Electronic Equipment European directive 2002 96 EC This symbol on the product or in the instructions means that the electrical and ...

Page 16: ...16 ...

Page 17: ...17 ...

Page 18: ...eet 21 Lancaster Pennsylvania 17607 5600 JB Eindhoven Singapore 573943 USA The Netherlands Singapore Tel 1 888 289 0096 Tel 31 40 2577 284 Tel 65 6258 5511 Fax 1 585 223 9180 Fax 31 40 2577 330 Fax 65 6258 4671 security sales us bosch com emea securitysystems bosch com apr securitysystems bosch com 2010 Bosch Security Systems data is subject to change without notice INST 177 Rev13 ...