14
Various switching configurations can be made using an interface cable.
Commonly used switching configurations are explained below.
Camera (or other switching device) leading
The illuminator may be activated remotely by a volt-free contact latched
across the TELEMETRY input. Use interface cable (UFLED-CI-5M).
Looping multiple illuminators
Multiple illuminators can be linked for synchronous illuminator switching.
Use link cable (UFLED-CL-1M) between the DAY/NIGHT CAMERA output
and the TELEMETRY input as shown in the diagram below.
Illuminator leading
The DAY/NIGHT CAMERA output may be used to switch the camera
between the Day and Night mode. Use interface cable (UFLED-CI-5M).
UFLED-CI-5M
Camera
Illuminator
UFLED-CI-5M
Illuminator
Camera
UFLED-CL-1M
UFLED-CL-1M
UFLED-CI-5M
Illuminator 1
Camera
Illuminator 2
Illuminator 3
6.
REMOTE
SWITCHING