![Bosch ACS 810 Repair Instructions Download Page 36](http://html.mh-extra.com/html/bosch/acs-810/acs-810_repair-instructions_50400036.webp)
| 36 | ACS 810 | Software
en
1 689 975 253
2021-01-26
|
Robert Bosch GmbH
16. Software
16.1 Vehicle database
i
The vehicle database can be updated annually
using a PS2 stick. Further information can be
obtained from customer service.
!
Do not switch off ACS 810 during update process.
!
Follow the additional ACS 810 menu prompting.
1.
Call up the start screen.
2.
Press <
3
> and <
Flush
> simultaneously and release.
The message
ENTER CODE 0000
is displayed.
3.
Enter 2222
and confirm with
E
.
4.
Select
"
DATABASE UPDATE
" with
o
u
and
confirm with
E
.
INSERT THE KEY
is displayed.
5.
Remove plastic cover (input PS2 stick) between
menu key and stop key.
6.
Insert PS2 stick.
7.
Activate or deactivate with
o
u
and confirm with
E
.
The update is performed.
"
Data base is updated.
i
Return with <
Stop
>.
16.2 Data backup
i
This function enables you to save ACS 810
configuration data before a software update. A data
backup avoids the need to recalibrate the ACS 810
after a software update.
!
Do not turn off the ACS 810 while saving.
!
Follow the additional ACS 810 menu prompting.
1.
Call up the start screen.
2.
Press <
3
> and <
Flush
> simultaneously and release.
The message
ENTER CODE 0000
is displayed.
3.
Enter 5599
and confirm with
E
.
4.
Select
"
BACKUP
" with
o
u
and confirm with
E
.
INSERT THE KEY
is displayed.
5.
Remove plastic cover (input PS2 stick) between
menu key and stop key.
!
Do not use the PS2 stick with the new software
version, as the stick is cleared before the data
backup.
6.
Insert PS2 stick.
7.
Confirm that any data on the stick will be deleted.
8.
After the backup, remove the stick.
"
The data is saved.
16.3 Software update
i
The software is updated using a PS2 stick. Before
updating, perform a data backup (see section 16.2)
so that the calibration data and settings for the
ACS 810 will not be lost.
1.
Turn off the ACS 810.
2.
Insert the "System Software" PS2 stick.
3.
Press and hold the <
MENU
> key.
4.
Turn on the ACS 810 and release the <
MENU
> key.
5.
The ACS 810 turns itself off after programming.
6.
Remove the PS2 stick.
7.
Turn on the ACS 810.
16.4 Loading a data backup
i
The calibration data previously saved (section 16.2)
can be reinstalled after the software update.
1.
Turn off the ACS 810.
2.
Insert the "Data Backup" PS2 stick.
3.
Press and hold the <
MENU
> key.
4.
Turn on the ACS 810 and release the <
MENU
> key.
5.
After recovery of the data, remove the PS2 stick
and attach the plastic cover.
6.