5
ELECTRICAL PREPARATION
Dishwasher Electrical Rating
s
t
l
o
V
z
t
r
e
H
s
e
r
e
p
m
A
s
t
t
a
W
0
2
1
0
6
5
1
0
5
4
,
1
)
x
a
m
(
Figure 4
21"
(533mm)
30"
(762mm)
Figure 5
3/8" - 1/2"
( 8mm - 13mm)
3" - 4"
( 75mm - 100mm)
Electrical Preparation
Electrical Shock Hazard
To avoid electrical shock, do not work on an
energized circuit. Doing so could result in serious
injury or death. Only qualified electricians should
perform electrical work. Do not attempt any work
on the dishwasher electric supply circuit until you
are certain the circuit is
de-energized.
Electrical Supply
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with all
national and local electrical codes and ordinances. The
dishwasher is designed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shall be a
minimum #14 AWG copper wire rated at 75°C or higher.
Regardless of where the electrical supply cable enters the
enclosure, position the cable 21” (533mm) from the
enclosure’s left side, as shown in
Figure 4
. Extend the
cable 30” (762mm) from the enclosure’s back, as shown
in
Figure 4
.
Remove 3” - 4” (75mm - 100mm) of the cable’s outer
casing, as shown in
Figure 5
, then remove 3/8” - 1/2”
(9 - 13mm) of insulation from each wire, as shown in
Figure 5
.
Fire Hazard
To avoid a fire hazard, make sure electrical work
is properly installed. Only qualified electricians
should perform electrical work.
WARNING
WARNING
Summary of Contents for 8504
Page 2: ......
Page 51: ...17 Notes ...
Page 52: ...18 Notes ...
Page 53: ...19 Notes ...
Page 54: ...20 90 00 06 37 16 8504 BSH Home Appliances Corporation 2005 Litho U S A 07 04 ...