24
| Controls
6 720 813 643 (2018/04)
▶ Touch the symbols
or
to choose the following information.
–
DH Data History
–
OD Operation Data
–
FH Failure History
–
AC Consumptions
–
HS About
▶ Touch the symbol
to selected the desired information.
DH Data History
Allows you to view two parameters:
•
Operation Cycles
- number of times burner has been started.
•
Operation Hours
- number of hours burner has been operational.
OD Operation Data
Allows you to view various parameters of the current operation of the appliance:
•
Chamber NTC
- current water temperature of the heat exchanger.
•
Inlet NTC
- current temperature of the temperature sensor of the water inlet
tube.
•
Outlet NTC
- current temperature of the temperature sensor of the water outlet
pipe.
•
Fan Speed
- current fan speed.
•
Flow - total flow, through main valve + bypass.
•
Output Power
- % current power.
•
Ambient NTC
- current temperature inside cabinet near the fan.
•
Exhaust Gas NTC
- Exhaust gas temperature sensor.
•
SS Hex NTC
- current temperature between condensing and copper heat
exchanger.
•
External Tank
- current temperature on the external tank.
•
Barometric pressure
- current barometric pressure at installation location.
FH Failure History
Allows you to view the last 10 error codes.
▶ Touch the symbol
.
Display shows the last 10 error codes.
If the display shows ellipsis (...) means that no error as occurred.
Summary of Contents for 7736504945
Page 19: ...Controls 19 6 720 813 643 2018 04 Safety information Fig 14 ...
Page 21: ...Controls 21 6 720 813 643 2018 04 5 3 Main menu structure Fig 16 User s menus ...
Page 22: ...22 Controls 6 720 813 643 2018 04 5 4 Service menu structure Fig 17 Service menus ...
Page 46: ...46 6 720 813 643 2018 04 Notes ...
Page 47: ... 47 6 720 813 643 2018 04 Notes ...
Page 48: ......