Cleaning
TR1000 12 B – 6 720 876 017 (2020/06)
12
• In order to compensate for this temperature reduction, please reduce
the water quantity on the tap until the required water temperature is
achieved.
8
Cleaning
• Simply wipe the appliance with a damp cloth.
Do not use acidic or abrasive cleaning materials.
Notes:
It is normally not necessary to descale the appliance. However,
extremely hard water and the frequent flows of very hot water can cause the
appliance to scale up. In this case please contact our after-sales service.
9
A fault, what to do?
WARNING:
Attention!
Repairs must only be carried out by an authorised technician. Improper
repairs can lead to risk of serious injury to the user.
If your appliance does not operate as required, it is often due to a very
minor problem. Please check whether you can remedy the fault yourself
by using the following guidelines. You will save yourself the costs of an
unnecessary visit by customer service personnel.
The water does not heat up or not enough water flows out of the tap:
• Check the fuse in the fusebox.
• Drop in pressure in the water mains. If the pressure is too low, the
appliance will not switch on.
• The strainer on the tap or shower head is blocked. Unscrew the
strainer and either clean or descale it.
• The corner valve is clogged. Turn on the hot-water tap fully and open
and close the corner valve several times. Then clean the filter in the
water tap.
• The heater needs descaling. Arrange for a service engineer to visit.
The continuous-flow heater switches off during the drawing-off of
water, resulting in a reduction in the water temperature:
• The washer inside the hot-water tap must be a non-swelling type.
If you cannot resolve the problem yourself, switch off the heater via the
fuse in the domestic wiring. Arrange for a service engineer to visit.
10
After-sales service
If you call the after-sales service for assistance, please specify the
E no.
and
FD no.
of your appliance.
These numbers can be found on the underside of the continuous-flow
heater.
11
Environmental protection/disposal
Environmental protection is a fundamental corporate strategy of the
Bosch Group.
The quality of our products, their economy and environmental safety are
all of equal importance to us and all environmental protection legislation
and regulations are strictly observed.
We use the best possible technology and materials for protecting the
environment taking account of economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific
recycling processes that ensure optimum recycling.
All of our packaging materials are environmentally compatible and can be
recycled.
Used appliances
Used appliances contain valuable materials that can be recycled.
The various assemblies can be easily dismantled. Synthetic materials are
marked accordingly. Assemblies can therefore be sorted by composition
and passed on for recycling or disposal.
Used electrical and electronic appliances
Electrical or electronic devices that are no longer
serviceable must be collected separately and sent for
environmentally compatible recycling (in accordance with
the European Waste Electrical and Electronic Equipment
Directive).
To dispose of old electrical or electronic devices, you
should use the return and collection systems put in place in the country
concerned.
12
Guarantee
The guarantee conditions for this appliance are as defined by our
representative in the country in which it is sold.
Details regarding these conditions can be obtained from the dealer from
whom the appliance was purchased. The bill of sale or receipt must be
produced when making any claim under the terms of this guarantee.
Subject to change without notice.
13
Data Protection Notice
We,
Bosch Thermotechnology Ltd., Cotswold Way,
Warndon, Worcester WR4 9SW, United Kingdom
process product and installation information,
technical and connection data, communication data,
product registration and client history data to provide
product functionality (art. 6 (1) sentence 1 (b)
GDPR), to fulfil our duty of product surveillance and for product safety
and security reasons (art. 6 (1) sentence 1 (f) GDPR), to safeguard our
rights in connection with warranty and product registration questions
(art. 6 (1) sentence 1 (f) GDPR) and to analyze the distribution of our
products and to provide individualized information and offers related to
the product (art. 6 (1) sentence 1 (f) GDPR). To provide services such as
sales and marketing services, contract management, payment handling,
programming, data hosting and hotline services we can commission and
transfer data to external service providers and/or Bosch affiliated
enterprises. In some cases, but only if appropriate data protection is
ensured, personal data might be transferred to recipients located
outside of the European Economic Area. Further information are
provided on request. You can contact our Data Protection Officer under:
Data Protection Officer, Information Security and Privacy (C/ISP),
Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY.
You have the right to object, on grounds relating to your particular
situation or where personal data are processed for direct marketing
purposes, at any time to processing of your personal data which is based
on art. 6 (1) sentence 1 (f) GDPR. To exercise your rights, please contact
us via
To find further information, please
follow the QR-Code.
Summary of Contents for 7736504685
Page 36: ...TR1000 12 B 6 720 876 017 2020 06 36 1 ...
Page 37: ...37 TR1000 12 B 6 720 876 017 2020 06 2 ...
Page 38: ...TR1000 12 B 6 720 876 017 2020 06 38 3 ...
Page 39: ...39 TR1000 12 B 6 720 876 017 2020 06 4 ...
Page 40: ...TR1000 12 B 6 720 876 017 2020 06 40 5 ...
Page 41: ...41 TR1000 12 B 6 720 876 017 2020 06 6 7 ...
Page 42: ......
Page 43: ......
Page 44: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...