Regulations
W 300-5 P – 6 720 821 103 (2018/10)
27
2.5
Product information
2.6
Product data for energy consumption
The following product data comply with the requirements of the EU
Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No.
814/2013 supplementing Directive 2010/30/EU.
3
Regulations
Observe the following guidelines and standards:
• Local regulations
•
EnEG (Building Regulations)
(in Germany)
•
EnEV (Energy Savings Order)
(in Germany)
Installation of, and equipment for, heating and water heating systems:
•
DIN
and
EN
standards
–
DIN 4753-1
– Water heaters ...; requirements, identification,
equipment and testing
–
DIN 4753-3
– Water heaters ...; corrosion protection on the
water side through glass lining; requirements and testing
(product standard)
–
DIN 4753-6
– Water heating systems ...; cathodic corrosion
protection for enamelled steel cylinders; requirements and
testing (product standard)
–
DIN 4753-8
– Water heaters ... , part 8: Thermal insulation of
DHW cylinders up to 1000 l rated content – requirements and
testing (product standard)
–
DIN EN 12897
– Water supply - regulation for ... DHW cylinders
(product standard)
–
DIN 1988
– Technical rules for potable water installations
–
DIN EN 1717
– Protection of potable water against
contamination ...
–
DIN EN 806
– : Technical rules for potable water installations
–
DIN 4708
– Central water heating systems
•
DVGW
– Code of Practice W 551 – Potable water heating systems and
pipework; technical measures to inhibit the growth of legionella
bacteria in new systems; ...
– Code of Practice W 553 – Sizing DHW circulation systems ... .
Continuous output (at 80 °C flow temperature, 45 °C DHW outlet temperature
and 10 °C cold water temperature)
kW
l/min
36.5
897
56
1376
Heat-up time at rated output
min
12
19
Maximum heat input
5)
kW
36.5
56
Maximum heating water temperature
°C
160
160
Maximum heating water operating pressure
bar
(positive)
16
16
Connection size, heating water
DN
R1"
R1"
Pressure drop diagram
1) Without recharging; set cylinder temperature 60 °C
2) Mixed water at draw-off point (at 10 °C cold water temperature)
3) Distribution losses outside the DHW cylinder are not taken into account.
4) The performance factor N
L
=1 according to DIN 4708 for 3.5 persons, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C.
Measured at max. heat output. If the heat output is reduced, N
L
becomes smaller.
5) In the case of heat sources with a higher heat output, limit to the stated value.
Unit
W 300-5 P
W 400-5 P
Table 4 Dimensions and specifications (
Fig. 1, page 55 and Fig. 3, page 56)
Item
Description
1
DHW outlet
2
DHW circulation connection
3
Cylinder flow
4
Sensor pocket for temperature sensor, heat source
5
Cylinder return
6
Cold water inlet
7
Heat exchanger for reheating by wall mounted boiler,
smooth enamelled tubing
8
Inspection aperture for maintenance and cleaning at the
front
Table 5 Product description (
Fig. 3, page 56 and Fig. 11, page 59)
9
Storage cylinder, enamelled steel
10
Magnesium anode with electrical insulation
11
PS top cover
12
Casing, painted sheet metal with rigid polyurethane foam
thermal insulation, 50 mm
Item
Description
Table 5 Product description (
Fig. 3, page 56 and Fig. 11, page 59)
Article number
Product type
Cylinder volume (V)
Heat retention loss (S)
Energy efficiency class
for DHW treatment
7 735 500 791
8718 542 832
W 300-5 P1 B
WST 300-5C B
300.0 l
300.0 l
B
7 735 500 793
8 718 541 939
W 400-5 P1 C
WST 400-5 C
380.9 l
88.3 W
C
Table 6