H
65
Circulation Pump / Motor Assembly
Fig. 16-6
Fig. 16-7
CIRCULATION PUMP / MOTOR REMOVAL:
Disconnect the four wire leads, then grasp the Circulation Motor and turn clockwise a quarter turn until
the Motor stops, Fig. 16-2. Now, remove the Motor / Rear Pump Assembly from the Front Pump
Housing, Fig. 16-3.
Note: The Front Pump Housing remains in place when the Motor is removed, Fig.16-3, item 1.
With the Motor / Rear Pump Assembly removed from the unit, separate the Motor from the Rear Pump
Assembly. To do so, first remove the Impeller by placing a block in the rear of the Motor and then turning
the Impeller counter-clockwise, then Fig 16-4.
The Rear Pump Assembly consists of four components, Fig. 16-5:
1.
Rear Pump Housing.
3. Impeller.
2.
Main Pump Seal.
4. Impeller Seal.
Each component can be replaced as an individual item.
TO INSTALL:
First, locate the Key Square on the Front Pump Housing, Fig. 16-6. Next, locate the Key Square Cut
Out on the Rear Pump Housing, Fig. 16-3, item 2.
When replacing the Pump / Motor make sure to line up the Key Square with the Key Square Cut Out.
Then bring the two pump halves together in the position shown in Fig. 16-2, and turn the Motor
clockwise until it stops, see Fig. 16-7.
Service note: The Impeller Seal Spring is compressed when the two halves of the Pump Assembly are
brought together. This will take a little force, so make sure to have a good grip on the
Sump as you compress the spring.
Now, reattach the wiring leads, test and check for leaks.
Summary of Contents for 3006
Page 10: ...8 H Notes ...
Page 20: ...18 H Notes ...
Page 26: ...24 H Interior Features Fig 5 11 Fig 5 12 1 2 2 Fig 5 7 Fig 5 8 Water Level Fig 5 9 Fig 5 10 ...
Page 38: ...36 H Notes ...
Page 60: ...58 H Notes ...
Page 66: ...64 H 2 1 Circulation Pump Motor Removal Fig 16 4 Fig 16 2 Fig 16 3 Fig 16 5 3 2 4 1 ...
Page 72: ...70 H Notes ...
Page 87: ...BSH Home Appliances 2800 South 25th Avenue Broadview Illinois 60153 ...