Assembly 23/40
3 842 564 350/2020-06, MIT: PE 2/X, PE 2/H, PE 4,
Bosch Rexroth AG
7.5.6
Connecting the pneumatics
WARNING
High pneumatic pressure!
Risk of serious injury to eyes and body parts from whipping hoses and sudden
compressed air release.
Switch off the compressed air supply to the relevant system component before
performing any maintenance or repairs.
Ventilate the pneumatic circuit of the relevant system component.
Secure the system against being unintentionally switched on again.
Wear safety goggles.
• For the compressed air specifi cation, see section 16.2.
Fig. 10: Pneumatic connection (shown here on PE 2/H) and pneumatic diagram
554 089-11
Y
X
1
3
5
2
4
1)
D8
D8
D8
D8
Y
X
Please note:
Use connections X
and Y.
This charges the system
more quickly and evenly.
• The pneumatic hoses on
all 4 ports must be the
same length!
Connect the positioning
unit to the directional
control valve.
1) Not included in delivery
EN
GLISH