Installation (only for approved contractors)
Tronic 4000 T – 6721843807 (2022/06)
36
5.3
Installing the appliance
It is obligatory to fix the appliance to the wall.
NOTICE
Risk of damage to property!
▶ Use screws and supports with specifications above the
weight of the appliance when the tank is full and which are
appropriate for the type of wall.
Vertical assembly
Fig. 9
Vertical assembly (wall hung assembly)
Table 6
5.4
Water connection
NOTICE
Risk of damage to property!
Risk of corrosion damage to the appliance's connections.
▶ Use galvanic isolators on the water connections. This will
prevent electric (galvanic) currents between the metals of
the hydraulic connections and, consequently, their
possible corrosion.
NOTICE
Risk of damage to property!
▶ Install a filter in the water inlet in locations where the water
presents suspended matter.
▶ When using PEX pipes, install a thermostatic control in the
outlet pipe of the appliance. This must be adjusted to match
the performance of the material used.
▶ The pipes used must be designed for 10 bar (1 MPa)
and 100 °C.
Recommendation:
▶ Flush the system before the installation since the presence
of sand particles can cause a reduction of the flow and
consequently the limit, and total obstruction.
▶ Make sure the cold and hot water tubes are duly identified,
in order to avoid confusion.
Fig. 10
[1] Cold water inlet (right)
[2] Hot water outlet (left)
Appliance
A
...50...
240
...80...
240
...100...
240
A
0010031730-001
1
2
0010031745-001