1 689 979 467
2012-10-10
|
Robert Bosch GmbH
Technical data | ��S ��� | 27
��S ��� | 27
| 27
en
7. Technical data
7.�
�ressure gauge
For pressure range, grade and diameter, see overview
on last but one page.
7.2
Test oil reservoir
Description
Value
Filling quantity of test oil reservoir
600 ml
Filter in test oil reservoir with purity
to ISO 4020-2
330 000 (ca. 15 µ)
7.�
Tightening torques
Fastening
Torque
Test pressure line on the EPS 100
15 + 10 Nm
Test pressure line on nozzle holder
15 + 10 Nm
Reducer on nozzle holder
15 + 10 Nm
Adapter on nozzle holder
15 + 10 Nm
Sealing screw for volume correction
50 + 10 Nm
Clamping screw on valve body (fastened to
base).
30 + 10 Nm
Left/right nut on pressure gauge
200 + 20 Nm
7.4
Glossary
Definition
Meaning
Stroke
Defined lever path
Specific delivery rate
Lever path x surface of delivery piston
Hydromechanical
rigidity
Dimensions of mechanism in con-
nection with hydraulic efficiency
(ISO: > 2.0 bar/mm lever path in Point S)
Volume elasticity
Acts on the hydromechanical rigidity in
dependence of the test fluid and the
damage level present.
Damage or total
damage level
The level inevitably caused by produc-
tion is theoretically required for the
function, although not necessary.