Fitting
Charging the battery (accessory)
Note:
The battery is supplied partially charged. To ensure
full battery capacity, fully charge the battery in the charger
before using your tool for the first time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
The lithium-ion battery is protected against deep discharge
by the "Electronic Cell Protection (ECP)". A protective circuit
switches the cordless worklight off when the battery is
drained.
u
Do not continue to press the On/Off switch after the
worklight has been automatically switched off.
The
battery can be damaged. Ensure that the battery is
charged and that the worklight has cooled before switch-
ing on the worklight again.
To remove the battery
(8)
, press the release button
(7)
(see
figure
A
) and pull the battery backwards and out of the cord-
less worklight.
Do not use force to do this.
Follow the instructions on correct disposal.
Battery charge indicator
The green LEDs on the battery charge indicator indicate the
state of charge of the battery. For reasons of safety, it is only
possible to query the state of charge when the cordless
worklight is switched off.
Press the button for the battery charge indicator or
to
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Battery model GBA 18V...
LEDs
Capacity
3× continuous green light
60−100 %
2× continuous green light
30−60 %
1× continuous green light
5−30 %
1× flashing green light
0−5 %
Battery model ProCORE18V...
LEDs
Capacity
5× continuous green light
80−100 %
4× continuous green light
60−80 %
3× continuous green light
40−60 %
2× continuous green light
20−40 %
1× continuous green light
5−20 %
LEDs
Capacity
1× flashing green light
0−5 %
Putting the Button Cell into Operation
(see figure A)
Remove the separating film between the button cell
(10)
and the button cell contact when using the tool for the first
time.
The cordless worklight is fitted with a button cell so that it
can be detected by the mobile device even if no battery
(8)
is inserted.
Unlock the locking mechanism of the battery cover
(6)
and
fold up the battery cover
(5)
.
Unscrew the screw of the battery compartment cover
(12)
and remove the battery compartment cover
(11)
.
Remove the film from the button cell contact and reattach
the battery compartment cover with the screw.
Operation
Start-up
Inserting the Battery
Unlock the locking mechanism of the battery cover
(6)
and
fold up the battery cover
(5)
.
Insert the charged battery
(8)
into the lamp head
(1)
until
you feel it engage and it is flush with the lamp head
(1)
.
Close the battery cover
(5)
and then the locking mechanism
of the battery cover
(6)
.
u
Make sure that the rubber lip is seated correctly when
closing the battery cover.
Otherwise protection against
dust and splash water will not be ensured.
Remove the battery cover (see figure B)
A very large rechargeable battery will prevent the battery
cover
(5)
from closing. In this case, the battery cover can be
removed.
Push the two hinges inwards against the spring force. Re-
move the battery cover.
There is no IP protection whilst
the battery cover is not in place!
To refit the battery cover, push the two hinges inwards
against the spring force again. Place the battery cover on the
housing. Allow the two hinge pins to engage in the openings
on the housing.
Setting up
Place the cordless worklight on a stable, level surface. Make
sure it is secure.
Hanging up
The notched carrying handle
(3)
can be used to hang up the
cordless worklight. Make sure it is hung up securely.
Fastening to the tripod
You can use the tripod mount
(4)
to screw the cordless
worklight onto a tripod.
1 609 92A 6TY | (27.08.2021)
Bosch Power Tools