MBC 2 – 6 720 810 583 (2014/02)

26

Notes

Summary of Contents for MBC 2

Page 1: ...Installatie instructie Instalation instructions Modulerende cascaderegelaar modulating cascade regulator MBC 2 II I MBC2 6 720 810 583 00 1TD nederlands 2 english 14 6 720 810 583 2014 02 nl en...

Page 2: ...nu aan verbetering van haar producten Wijzigingen in figuren tekst en technische gegevens zijn dus mogelijk Inhoudsopgave 1 Leveringsomvang 3 2 Omschrijving 3 2 1 Algemeen 3 2 2 Centrale verwarming 3...

Page 3: ...tetemperatuurregeling modulerende weersafhankelijke regeling HetregelprincipewordtnietbepaalddoordeMBC2 maardoorhettype ModuLine iRT thermostaat dat op de MBC 2 wordt aangesloten Modulerende ruimtetem...

Page 4: ...he radiatorafsluiter vuilafscheider MBC 2 afsluiter haaks eerste cv toestel tweede cv toestel handontluchter afsluiter recht systeempomp aanvoertemperatuursensor inregelafsluiter radiator ModuLine iRT...

Page 5: ...ogrammeerbaar is Deze ModuLine iRT thermostaat moet als weersafhankelijke rege ling worden geprogrammeerd Zie hiervoor de gebruikers en instal latie instructie van de ModuLine iRT thermostaat Alle ver...

Page 6: ...ecv toestelplus het geleverd vermogen van het tweede cv toestel gelijk is aan het gevraagd vermogen van 50 Lijn J Bij een warmtevraag van de ModuLine iRT thermostaat van 50 zal het tweede cv toestel a...

Page 7: ...Voor beide manieren geldt dat indien de wachttijd voor het inschakelen van het tweede cv toestel zodanig is ingesteld dat deze langer is dan de anti pendeltijd dan vervalt de antipendeltijd en geldt d...

Page 8: ...et storingscontact geopend In geval van een vergrendelende toestelstoring of spanningsonderbreking valt het storingsrelais af waardoor het storingscontact wordt gesloten Op de MBC 2 zal hierdoor de st...

Page 9: ...2 5 Schakelvolgorde al gemeen wachttijdvoorhetinschakelenvanhettweedecv toestel Zie 2 2 6 Wachttijd voor het inschakelen van het tweede cv toestel Het instellen van de automatische volgordeomkering Ga...

Page 10: ...httijd is 30 minuten Zie afb 8 Monteerdeonderste endebovensteafdekkap Zie 3 2 Montage 6 720 810 583 08 1TD aanvoertemp sensor ModuLine iRT thermostaat buitentemp sensor externe storings signalering cv...

Page 11: ...abel 1 De storingscodes zijn vermeld in tabel 2 Zie voor nadere informatie over deze gegevens en het uitlezen ervan de gebruikersinstructie van de ModuLine iRT thermostaat 4 1 3 Storingssignalering vi...

Page 12: ...troleer de buitentemperatuur sensor Zie tabel 4 De storingscode van dit cv toestel Knippert snel 8x per seconde Gesloten lamp of bel wordt bediend Brandt E n cv toestel in vergrende lende of blokkeren...

Page 13: ...cv toestel 1 cv toestel 2 mm mm mm mm mm mm mm max 2 5 max 2 5 max 1 5 max 1 5 min 0 75 max 1 5 min 0 75 max 1 5 min 0 75 max 1 5 Kabellengte 1 ModuLine iRT thermos taat 2 cv toestel 1 2 cv toestel 2...

Page 14: ...manufacturer works continuously to improve its products Changes in the figures the text and technical specifications are therefore possible Table of contents 1 Packaging 15 2 Description 15 2 1 Genera...

Page 15: ...ture regulation modulating weather dependent regulation The regulation principle is determined not by the MBC 2 but by the type of ModuLine iRT thermostat that is connected to the MBC 2 Modulating roo...

Page 16: ...ator valve waste separator MBC 2 angle valve first boiler second boiler manual ventilator upright valve system pump supply temperature sensor balancing valve radiator ModuLine iRT thermostat central h...

Page 17: ...RT thermostat must be programmed as a weather dependent regulator For this see the user and installation instructions for the ModuLine iRT thermostat Each room with heating units must be provided with...

Page 18: ...is equal to the required output of 50 LineJ IntheeventofademandforheatfromtheModuLine iRT ther mostat of 50 the second boiler will be switched off and at the same time the first boiler will modulate...

Page 19: ...ing weather dependent regulation The following applies to both ways If the waiting time for switching on the second boiler is set so that it exceeds the anti cycling time the anti cycling time will be...

Page 20: ...t free contact During a normal operating situation the fault contact is opened In the event of a locking boiler fault or an interruption in the voltage the contact fault relay de energisessothatthefau...

Page 21: ...2 3 3 2 Settings general Two settings can be entered on the MBC 2 automatic reverse of sequence See 2 2 5 Switching sequence general waiting time for switchingonthe second boiler See 2 2 6 Waiting tim...

Page 22: ...right waiting time is 30 minutes See fig 8 Mount the bottom and top guards See 3 2 Assembly 6 720 810 583 31 1TD supply temp sensor ModuLine iRT thermostat outside temp sensor external fault reportin...

Page 23: ...2 Table 2 list the fault codes Forfurtherinformationregardingthesedataandtheirread outs seethe user instructions for the ModuLine iRT thermostat 4 1 3 Remote fault reporting via the integrated fault...

Page 24: ...tempera ture sensor and the MBC 2 Check the outside temperature sen sor See table 4 The fault code for this boiler Flashes rapidly 8 x per second Closed lamp or bell activat ed Lit up Locking or block...

Page 25: ...ModuLine iRT thermostat boiler 1 boiler 2 mm mm mm mm mm mm mm max 2 5 max 2 5 max 1 5 max 1 5 min 0 75 max 1 5 min 0 75 max 1 5 min 0 75 max 1 5 Cable length 1 ModuLine iRT thermostat 2 boiler 1 2 bo...

Page 26: ...MBC 2 6 720 810 583 2014 02 26 Notes...