Online measurement
106
11.3.2
Performing the online offset calibration
DDU 7 has to be connected to RaceCon to calibrate the sensor’s offset.
1.
Apply the desired physical condition to the sensor. (e.g. 1 G to an acceleration sensor)
2.
Open the measurement channel’s online page by double-clicking on the measurement channel
name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the ‘Calibrate’ button.
The sensor’s offset is now calibrated.
11.4
Group adjustment
Group adjustment is the simultaneous online calibration of several channels. This is useful e.g. to
set all wheel forces and damper positions to ‘0’ when the vehicle is positioned on a flat patch.
11.4.1
Configuration of group adjustment
Group adjustment consists of two components:
•
An input channel which triggers the adjustment event
•
A group of input channels linked to the group adjustment event
Calibration
target value
Initiate
calibration