background image

Page 12

Ws

un

ąć

Ws

un

ąć

Ws

uną

ć

Ws

uną

ć

VII. Assembly and installation

1. After taking out of the carton, remove unnecessary packaging 

and elements protecting the product and read the instructions.

2. Screw two handles to carry the device.

3. Screw the handle to open the door.

Summary of Contents for BBDST-150

Page 1: ... use Before using the device read the instructions MANUAL FOR SMOKERS BBDST 70 BBDST 150 UWDT 70 UWDT 150 I Safety requirements and precautions II Terms of use III Technical parameters IV Composition of the set V Construction and description of the operation VI Operation of the electronic control panel VII Assembly and installation VIII First start IX Maintenance X Regulations XI Vorschriften The ...

Page 2: ...protected with an earth leakage circuit breaker with Ir or 30 mA Power cords of the device should be arranged in such a way that they are not in contact with hot parts of the housing The smoker is intended for outdoor use but it must not be exposed to atmospheric precipitation and strong gusts of wind The optimal solution is to work in roofed sheltered and at the same time ventilated places Do not...

Page 3: ... manufacturer may result in injury or damage to the device for which the manufacturer is not responsible Be careful with sharp edges when assembling and disassembling the device Do not use the device contrary to its intended use The device is intended for home use Do not leave the device switched on after finishing smoking The device should be inaccessible to animals Do not allow children to use t...

Page 4: ... an extension cord Protect against rain and water access After each use switch off the device from mains power supply if it is not used Thoroughly clean the smoker after each use Do not cover or put anything on it when the device is in use Empty the bowl for ash and fat every 2 3 hours and fill it with fresh water The socket outlet from which the device is to be powered should be protected with an...

Page 5: ...0A 1 25A 8A 1 25A 10A 1 25A 1 25 A Chamber capacity 70L 70L 150L 150L 2L Maximum temperature 120 C 150 C 120 C 150 C The Degree of the housing tightness IP20 TECHNICAL PARAMETERS OF THE SMOKER Width mm 630 720 360 Depth mm 400 520 180 Height mm 1040 1220 250 OVERALL DIMENSIONS EXTERNAL Width mm 400 490 Depth mm 300 420 Height mm 580 755 DIMENSIONS OF THE CHAMBER INTERNAL 630 720 440 530 360 480 40...

Page 6: ... Water bowl 2 pcs Chimney with an air damper Illustrative drawings do not reflect the actual dimensions of the parts the plug type depends on the distribution country type of product and quantity dependent on the set Power cord EU C13 GN tray only BBQ version Crossbars for hanging 3 pcs A 10 1 A Cover for the generator Wood chips 2x2L Smoker rack Smoking hooks Power cord C12 C13 Power cord EU C13 ...

Page 7: ... the feeder 7 starts to rotate at the same time the burner 6 begins to heat The feeder uniformly transports chips from the storage tank 2 to the burner where they start to smoulder Smouldering chips are pushed through the entire length of the burner 6 where at the end they fall into a container filled with water 8 9 7 6 4 1 5 3 2 10 Using a smoker does not require any special skills and the perfec...

Page 8: ...d one is used to collect the juices from smoked meats The ambient temperature and wind have a large impact on the operating conditions of the device In unfavourable atmospheric conditions the chamber heating time may increase It is advisable to use an independent thermometer to measure the temperature inside the smoked product The consumption of materials for the production of smoke is small for a...

Page 9: ...device with the button 8 Turn on the heat Start the control panel with the button 8 Press 2 on the control panel The lamp of heating function button will light up The heating function is switched on Turn on the smoke generator Before switching on make sure that the generator is positioned according to the instructions from chapter VII Assembly and installation Turn on the power button on the smoke...

Page 10: ...rts flashing When the countdown ends the device turns off Time view for a specific function The illuminated symbol 4 shows the function for which the time is shown on the display 1 Turn the knob 5 to change the lit icon 4 and the operating time shown on the display 1 Pressing turns the heater on off Press for approx 2 seconds time setting The lamp is on heating is on The lamp flashes the heater is...

Page 11: ...f temperature probe Turn off the device Disconnect the power cord from the power supply The error should be reported to the seller or service Error temperature probe not detected Turn off the device Disconnect the power cord from the power supply Check the connection between the cabinet and the panel If the error persists report it to the seller or service The lower right dot indicates the operati...

Page 12: ...nąć VII Assembly and installation 1 After taking out of the carton remove unnecessary packaging and elements protecting the product and read the instructions 2 Screw two handles to carry the device 3 Screw the handle to open the door ...

Page 13: ...under the chimney 8 Insert the drip tray onto the bottom rack 9 Mount the electronic control panel see the description p 14 Wsunąć Wsunąć Wkręci Wkręci N a ło ż y ć i N a ło ż y ć i z a c z e p ić z a c z e p ić Wsunąć Wsunąć ręcić ręcić Wsunąć i Wsunąć i dokręcić dokręcić Wsunąć Wsunąć Wsunąć Wsunąć When smoking very fatty foods on the grates please use an additional drip tray or metal bowl over ...

Page 14: ...2 4 hours Connect the generator and the smoker to 230V mains with protective grounding Switch to start the smoke generator and the smoking unit on the electronic panel set the temperature to approx 80 C see Operation of the electronic control panel Heat the smoker for about 2 hours This will reduce technological odours and ensure initial flavouring of the device After heating you can start the pro...

Page 15: ... ignite NOTE When smoking excess fat falling very fat products control on the shutter it must be removed unconditionally NOTE During the operation of the device carbon deposit forms on the part of the sawdust feeder It should be removed after 8 hours of the generator operation using a scraper pliers or other blunt tool Failure to remove carbon deposits can result in poor operation of the device an...

Page 16: ...the smoke generator burner Do not connect the smoker chimney outlet to chimneys ventilation shafts or other extensions of the smoke outlet due to the possibility of producing draft in the smoker which can cause wood chips to ignite The only way that is acceptable for extending the smoke outlet is to apply a hood over the smoker so that smoke can be extracted from the smoker at its own speed Igniti...

Page 17: ...sories in its original packaging 6 When sending in your defective appliance for service a valid Warranty Card without any traces of changes or interference must be included 7 Damage resulting from events such as lightning strike power surge in power lines mechanical impacts fires flooding or other uncontrollable events beyond the Seller s control are not covered by this warranty 8 The User shall d...

Reviews: