40
Auxiliary connections
The picture below shows a detail of the auxiliary connections.
There are 5 connectors. Each connector has a specific use:
-
Connector 0: Frequency output connection for grid-connected
inverters. This connector is NOT used in the MPPT charger.
-
Connector 1: This is a connector for RS232 communication. To be
able to use it, it is necessary to change the configuration of the
unit.
-
Connector 2: This connector has several functions. From left to
right the connections are:
o
Anemometer: This connection is to be able to monitor
wind speed. In some configurations this connection is
mandatory.
o
Manual brake: These two connections are to stop the
wind turbine manually; The manual brake performs the
same function as the red manual brake button.
EN
G