background image

 

 
 

Fixation

 

plate

 

 

This

 

plate

 

is

 

provided

 

to

 

be

 

attached

 

to

 

the

 

tower.

 

A n o th e r

 

o n e

 

is

 

a s s e m b l e d

 

o n

 

the

 

wind

 

turbine

 

base.

 

Its

  

function

  

is

  

to

  

secure

  

wind

  

turbine,

 

offering

   

an

   

ease

   

of

   

installation

   

a n d

 

removal

 

from

 

the

 

tower

 

at

 

any

 

moment.

 

T h e

 

plates

 

a r e

 

m a d e

 

w i t h

 

slots

 

to

 

a l l o w

 

the

 

cables

 

to

 

pass

 

through

 

without

 

twists.

 

They

 

are

 

attached

 

with

 

Allen

 

bolts

 

and

 

six

 

holes

 

are

 

provided

 

for

 

six

 

M 10x40

 

Allen

 

bolts,

 

with

 

M 10

 

w ashers

 

on

 

both

 

faces

 

and

 

six

 

M 10

 

nuts.

 

The

 

bolts

 

set

 

and

 

tower

 

plate

 

are

 

served

 

in

 

an

 

independent

 

plastic

 

bag,

 

if

 

not

 

mailed

 

before.

 

 

 

 

 

 

 

 
 

Tail

 

/

 

Tube

 

tail

 

 

The

  

tail

  

is

  

made

  

to

  

keep

  

the

  

wind

 

turbine

 

facing

 

into

 

the

 

wind

 

at

 

any

 

time.

 

 

T h e

  

tail

  

is

  

m a d e

  

of

  

t w o

  

different

 

pieces:

 

a

 

polyethylene

 

vane

 

and

 

a

 

steel

 

boom.

  

T h e y

  

are

  

put

  

together

  

with

 

three

 

M 6x80

 

bolts,

 

six

 

wide-series

 

M 6

 

washers

 

on

 

both

 

sides

 

of

 

the

 

vane,

 

and

 

three

 

M 6

 

self-locking

 

nuts.

 

 

 

 

 

 
 

37

 

EN

G

 

Summary of Contents for WIND 13+

Page 1: ...Wind 13 Manual Installation Operation Maintenance 25...

Page 2: ...Wind Turbine Components 29 Datasheet 30 Placing your wind turbine 32 Installation 32 The Tower 33 Electrical wiring 35 Installing the Wind Turbine 36 Maintenance 41 Frequently ask questions 43 Annex...

Page 3: ...conditions are located at the end of this manual They are dependent on the proper installation of your wind turbine as this will ensure the correct functioning of the apparatus and of course correct...

Page 4: ...ails for the right functioning of the system Hazards or unsafe actions that could cause an injury to your system or yourself Identification Each wind turbine is labeled with its model voltage and seri...

Page 5: ...al box you will find the components listed below Some items may already assemble 1 Tail 1 Tail tube 1 Nacelle 1 Alternator 1 Hub 2 Blades 1 Frontal cone 1 Set of bolts 1 Fixation plate Blade Alternato...

Page 6: ...W Nominal voltage 220 v 220 v 220 v Nominal RPM 600 400 400 Wind speed Operating range 2 30m s Turn on 3 m s Nominal power 12 m s Automatic brake system 14 m s Maximum 60 m s Physical specifications W...

Page 7: ...Model A mm B mm C mm D mm E mm Wind 13 1430 1670 370 470 2040 Wind 25 2 2000 2140 470 645 2610 Wind 25 3 2000 2640 495 645 3135 31 ENG...

Page 8: ...rbulences The best place for a wind machine is an obstruction free area and at the maximum height available Installation Before you begin run through the steps to follow in order to correctly assemble...

Page 9: ...r is in place 3 or 4 tensile guy cables are applied their supports firmly anchored to the ground generally in concrete foundations Check at all times that your tower remains perfectly vertical The guy...

Page 10: ...nce the wind turbine has been installed on the tower check that it can turn freely and that there are no obstacles within the diameter of the blades Under wind pressure the blades can have up to 15cm...

Page 11: ...the installation to be carried out Different types of batteries exist In the case of domestic hybrid wind energy solar energy installations open lead acid batteries are recommended and to meet the ins...

Page 12: ...e the electrical wiring installed we will proceed to assemble the wind turbine To ease installation of the wind turbine on the tower a bracket and pulley system should be used This system must securel...

Page 13: ...ached with Allen bolts and six holes are provided for six M 10x40 Allen bolts with M10 washers on both faces and six M10 nuts The bolts set and tower plate are served in an independent plastic bag if...

Page 14: ...hexagonal M8x60 bolt with two M8 washers one in each side and an self locking M 8 nut Tighten both to 2 5 Kg Nacelle The nacelle protects the alternator from external climatologically agents The nace...

Page 15: ...external bolts will be M10x55 while the central internal bolt now installed is M10 Once installed the blades must be adjusted Without using any nuts or washers the aluminum hub reinforcement layer is...

Page 16: ...l panel on windy days Do not leave the wind turbine run freely disconnected from the batteries this could damage the charging system If you need to disconnect the wind turbine from the batteries alway...

Page 17: ...justing the torque required for every bolt Checking state of wiring Visual inspection of blades Checking that the automatic breaking system works properly by tilting it manually The main wind turbine...

Page 18: ...ks by promoting fast braking and slow return to its original position The shock absorber has a little slack at the beginning of its return movement and this is normal However if this slack is observed...

Page 19: ...with other components to form a complete installation These components are usually Solar panels energy production Solar regulators to control battery charge from the solar panels Batteries accumulatio...

Page 20: ...protection be installed between the wind turbine and the regulator or between the regulator interface and the battery No never The regulator interface is already carrying out these protective functio...

Page 21: ...ight breeze 3 3 4 5 2 13 18 Gentle breeze 4 5 3 7 4 19 26 Moderate breeze 5 5 7 9 8 27 35 Fresh breeze 6 9 9 10 4 36 44 Strong breeze 7 12 5 15 2 45 54 Near gale 8 15 3 18 2 55 65 Gale 9 18 3 21 5 66...

Page 22: ...adversely affected by turbulence and light winds To maximize the performance of your wind turbine it should be installed as far as possible from the obstruction and atop a tower higher point from this...

Page 23: ...ators have been produced in compliance with regulations applicable under the E U directives 89 392 CEE 91 368 CEE And in accordance with the safety regulations for small wind power turbines UNE EN 614...

Page 24: ...cessories is 36 months from date of original installation or 40 months from fabrication date WARRANTY CONDITIONS The Warranty covers parts and labour in our workshops only The wind turbine must be ret...

Reviews: