EN
WWW.BORMANNTOOLS.COM
9
WARNING:
Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go. Unintentional startup can result in en
-
tanglement, traumatic amputation or laceration. Broken bones, fractures, bruises or sprains.
If the electric starter fails to start the engine, immediately turn off the starter. Don't attempt to restart the engine before the failure cause is identified. Don't
restart the engine by replacement of other storage battery without authorization.
CAUTION:
If the engine fails to start after attempt for 3 times or flames out after starting, inspect and ensure that the generator is placed in horizontal surface
and enough engine oil ls injected. During starting, don't keep the starting switch to "start" position for more than Ss, and otherwise it is possible to damage the
motor. If the unit fails to start within first time, restart after about 1 Os. After the unit is used for a period, if the starting speed of the motor falls, please replace
the battery. During the operation of the unit, the battery supplies power for the solenoid valve of the carburetor. For this, when the unit is turned off, make sure
that the starting switch is in "OFF" position and otherwise the storage battery voltage is reduced due to the operating solenoid valve of the carburetor, acting on
starting for next time. If the engine Is equipped with an engine oil alarm, it is possible to prevent engine start when the engine oil in the crankcase is lower than
the minimum level. During running-in, routinely inspect the engine oil. See maintenance section for recommended maintenance period.
7.
The generator may be normally loaded.
6.
When the engine operates stably, pull the choke valve
to "
OPEN
" position.
WARNING:
Connect the output terminal of the
generator with the electric equipment. Don't start or
stop the engine when the electric equipment is in "
ON
"
status.
VFT meter
(If applicable): The VFT meter can be used for displaying voltage, frequency(hertz), run time, and total run time as
applicable. (Display mode depends on the configuration). The LCD displays each mode by pressing the button below the display. The
display meter sets as either automatic switching mode or manual operation mode. In the manual state, press MODE BUTTON for
mode switching; But in automatic mode, MODE BUTTON is used for reset (operate cautiously when necessary).
a. Output voltage of the generator.
c. Run time (R):
Run time of the generator for the current session.
7.
The generator may be normally loaded.
b. Frequency (F):
The generator may be normally loaded.
Note: If display value is less than 100,the numeric display will
accurate to one decimal place. If the operation time Is 100 hour
or greater, the display will be "101","100" and so on.
Summary of Contents for 034414
Page 31: ......