BorMann 030386 Manual Download Page 5

EN

WWW.BORMANNTOOLS.COM

5

Automatic mode:

In automatic mode, the heater will start“open window temperature sensing”status, its description as below:

“open window temperature sensing” description:

When the heater is working with full power (four tubes all light up), if sensor detects the ambient temperature continuous decline 5

o

C within 300 seconds, 

two tubes on heater will go out and other two tubes will keep light up, the open window indication“ ”lights up, user can close open window indication by any 

button, then the heater resume heating with full power (four tubes all light up).

User can press “MODEL” to enter automatic mode, the automatic indication“ ”light up, the heater starts working with all power that 2200W.

User can press “+”and “-” to free adjust set temperature 15

o

C to 32

o

C,display flicker and show the set temperature. Waiting 5 seconds later or directly press“-

SETTING”, the set temperature is confirmed and exit adjustable condition. The heater starts working and heating. (Note:when the set temperature higher than 

ambient temperature(the ambient temperature you can see on display when the heater starts up ), the heater will starts working with full power (four tubes all 

light up). When the set temperature below ambient temperature, two tubes on heater will go out and other two tubes will keep light up)

Sleep Mode:    

In sleep mode, the heater will start“product temperature sensing” status and “open window temperature sensing” status, their description as below:

“product temperature sensing” description:

The fixed ambient temperature of product sensing is 28

o

C, When the sensor detects the ambient temperature is higher than 28

o

C, two tubes on heater will go 

out and other two tubes will keep light up. When the sensor detects the ambient temperature is below 28

o

C, the heater will resumes working with full power 

(four tubes all light up).

“open window temperature sensing” description:

When the heater under working status, if sensor detects the ambient temperature continuous decline 5

o

C within 300 seconds, two tubes on heater will go out 

and other two tubes will keep light up, the open window indication“ ”lights up, user can close open window indication by any button, then the heater resume 

heating with full power (four tubes all light up).

User can press “MODEL” to enter sleep mode, the sleep indication light up, the heater starts working with full power that 2200W. ???Yes

User can press “SETTING” to set timing, when time light flicker, user press “+” and “-” to adjust timing 1 hour to 15 hours, and every adjustable space is 1 hour. 

After you set timing, and wait 5 seconds or directly press “SETTING”, timer will works, time indication light up, and display show the countdown condition. User 

can press “SETTING” again, timing will be re-set. After countdown finish, the heater stops working and returns to standby condition.

Power Saving Mode

In power saving mode, user can set weekly timing and temperature according to their own needs. the operation as below:

User can press “MODE” to enter power saving mode, the power saving indication light up.

User can press “+” and “-” to free adjust set temperature 15

o

C to 32

o

C,display flicker and show the set temperature. Waiting 5 seconds later or directly press 

“SETTING”, the set temperature is confirmed and exit adjustable condition. The heater starts working and heating. (Note: when the set temperature higher than 

ambient temperature (the ambient temperature you can see on display when the heater starts up ), the heater will starts working with full power (four tubes 

all light up). When the set temperature below ambient temperature, two tubes on heater will go out and other two tubes will keep light up).

Time calibration setting

In power saving mode, the power saving indication light up.

User can press “SETTING” to set the time to the current time. User press “+” or “-” to adjust current date from Monday to Sunday. ( If today is Monday, user 

can set date to “Mon” ,and the indicator lights up.) Then press “SETTING” again,the date is confirmed and enter time setting condition.  

User can set hour by press “+” ( 24 hours a day, every adjustment increase one hour and repeat this cycle ), and set minute by press “-” (60 minutes an 

hour,every adjustment increase one minute and repeat this cycle). If current time is 12:00, user need adjust time to 12:00. 

Weekly timing setting

After time calibration, user can press “SETTING” again to set the start date of weekly timing, user can press “+” and “-” to set start date from Monday to Sun-

day, then press “SETTING” again to confirm the start date that you set. Besides, “ON” will be showed on display, then user can set start time.

When “ON” is displayed, user can set hour by pressing “+” (24 hours a day, every adjustment increase one hour and repeat this cycle ), and set minute by 

press “-” (60 minutes an hour,every adjustment increase one minute and repeat this cycle), then press “SETTING” again to confirm the start time that you set. 

Besides, “OFF” will be showed on display, then user can set stopped time.

When “OFF”is displayed, user can set hour by pressing “+” (24 hours a day, every adjustment increase one hour and repeat this cycle), and set minute by press 

“-” (60 minutes an hour,every adjustment increase one minute and repeat this cycle), then press “SETTING”again to confirm the stopped time that you set. 

Besides, the heater re-enter timing setting condition to set next timing.

If user need timing in other day, user can completely re-operates (2-1) (can press “+”and“-”to set date), (2-2), (2-3), (2-4).   

When user completes setting, press and hold the “setting” for 2 seconds, the heater will exit weekly setting condition, and timer starts. Display show the 

current time, and clock light up.

When time show on display reaches start time that user set before, the heater will works under temperature that set before. When time show on display 

reaches stopped time that user set before, the heater will stops working.

Summary of Contents for 030386

Page 1: ...WWW BORMANNTOOLS COM GB GR BEH7300 BEH7200 BEH6100 030386 030393 030409...

Page 2: ...O FUNCTION SLEEP MODE ENERGY SAVING MODE TEMPERATURE WEEKLY SCHEDULE PROGRAM TIME TIMER OPEN WINDOW INDICATION HEATING LEVEL CLOCK Components 1 Top Heating Power Switch 2 Other Sides Power Switch 3 Ca...

Page 3: ...late to the bottom of the heater by using the wing nuts Return the appliance to upright position WARNING Operate the appliance in normal upright position only with wheel assemblies attached to the bot...

Page 4: ...mode user can free switch any mode in below 4 modes Mode operation Normal mode In normal mode the heater will start product temperature sensing status and open window temperature sensing status their...

Page 5: ...condition Power Saving Mode In power saving mode user can set weekly timing and temperature according to their own needs the operation as below User can press MODE to enter power saving mode the powe...

Page 6: ...light up Before reaches the appointment starting time the heater works with half power only two tubes light up Until the heater reaches the appointment starting time four tubes will be all light up th...

Page 7: ...GR WWW BORMANNTOOLS COM 7 1 2 3 4 5 1 2 3 4 5 BEH7300...

Page 8: ...GR WWW BORMANNTOOLS COM 8 Service BEH6100 BEH7200 BEH7300 220 240V 50 60Hz 220 240V 50 60Hz 220 240V 50 60Hz 1100w 2200w 1100w 2200w 1100w 2200w LCD BEH6100 BEH7200 1...

Page 9: ...GR WWW BORMANNTOOLS COM 9 I II OFF High Heat Low Heat 1 2 3 4...

Page 10: ...GR WWW BORMANNTOOLS COM 10 BEH7300...

Page 11: ...GR WWW BORMANNTOOLS COM 11...

Page 12: ...GR WWW BORMANNTOOLS COM 12...

Page 13: ...GR WWW BORMANNTOOLS COM 13...

Page 14: ...GR WWW BORMANNTOOLS COM 14 EL Service...

Page 15: ......

Reviews: