8
www.BormannTools.com
Table5-1 Diagnose and solutions
TROUBLE
REASON
SOLUTION
Without output
1.Without voltage in input terminal
2.Improper fuse or breaker
3.Overload protective setting
1.Check the fuse or breaker
2.Replace fuse or breaker
3.After cooling then try to continue
Bad wire-feed
1.Have not enough pressure
2.Wing hat is too loose
3.Wire has been oxide
1.Tighten the impaction nut
2.Tighten wing nut
3.Replace wire spool
Current is too poor
1.Input voltage is too poor
2.Bad connection
3.One or more commute element
have been damaged
1. Check that if input voltage is the same
with rated voltage.
2. Check grounding cable and make sure
have well connection.
3. Replace by career.
The welder line is
like sponge
1.No gas or little gas
2. The hole has been blocked.
3. Haitian valve has been blocked.
4.Bad gas and wire
1.Check all gas
2.Use compress air to clear
3.Open the welding torch and
4. Gas must be dry, use another type
wire.
When Pressing
switch the machine
cannot working
1. Control wire broke off
2. Circuit plate damaged.
1.Check by career
2.Replace circuit plate
Summary of Contents for 022749
Page 1: ...BIW1130 MIG Owner s manual Art Nr 022749 www BormannTools com...
Page 2: ...2 www BormannTools com GR 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 1 2 3 1 2 3 4 5...
Page 5: ...5 www BormannTools com 2 1 ON OFF OFF ON OFF 15 1 2 ON OFF OFF 230VAC 15A ON OFF...
Page 6: ...6 www BormannTools com 3 4 H 5 30mm 6 7 8 9 10 35 3 3 3 3 12 OFF 13 OFF 15 Service OFF...
Page 7: ...7 www BormannTools com Service Service Service...
Page 15: ...9 www BormannTools com...
Page 16: ...10 www BormannTools com...
Page 17: ...11 www BormannTools com...