background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIW1130

 |

 

ΗΛΕΚΤΡΟΚΟΛΛΗΣΗ MIG

 

 

Μετάφραση του πρωτοτύπου των 

οδηγιών χρήσης 

 

 

 

 

   

 

Owner’s manual 

Art Nr: 

022749

 

 

www.BormannTools.com 

 

Summary of Contents for 022749

Page 1: ...BIW1130 MIG Owner s manual Art Nr 022749 www BormannTools com...

Page 2: ...2 www BormannTools com GR 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 1 2 3 1 2 3 4 5...

Page 3: ...3 www BormannTools com 1 2 3 1 2 3 4 5 6 MIG 1 1 V A 100 V A 230V 50Hz 30V 45 130A 130A 10 0 6 0 9MM IP21S1...

Page 4: ...4 www BormannTools com 10 C 40 C 25 C 1 55 C 40 C 50 20 C 90 d 1000m e 15 75 decibel 46cm 1 2 3 4...

Page 5: ...5 www BormannTools com 2 1 ON OFF OFF ON OFF 15 1 2 ON OFF OFF 230VAC 15A ON OFF...

Page 6: ...6 www BormannTools com 3 4 H 5 30mm 6 7 8 9 10 35 3 3 3 3 12 OFF 13 OFF 15 Service OFF...

Page 7: ...7 www BormannTools com Service Service Service...

Page 8: ...he working cable and working piece are connected 4 To change the damaged or abrasion cable in time 5 Keep dry including cloth working area wire welding torch soldering turret and power supply 6 Keep t...

Page 9: ...s inevitable WARNING Means potential danger it also get people injured or dead CAUTION Means danger it can get people injured Produce application The MIG welding machine adopts special tapped transfor...

Page 10: ...protect your eyes and face MIG Torch We provide one MIG Torch Earth Clamp In order to operate conveniently we provide one earth clamp Specific packing please sees the packing list the last page of the...

Page 11: ...en welding you must wear helmet glove and other guard ON OFF switch When the switch on OFF position means power has been closed when the switch on ON position means supply power for the main transform...

Page 12: ...light Step 5 Press and hold the torch button until distance between wire and welding torch is 30mm loosen torch button Step6 Close the power fix the contact tip and nozzle cover onto the welding torch...

Page 13: ...ary to keep the alleyway cleanness After cleaning by low pressure check if any hard ware has flexible if been flexible you must firm them include all electric contactor Check if insulation of cable ha...

Page 14: ...rrent is too poor 1 Input voltage is too poor 2 Bad connection 3 One or more commute element have been damaged 1 Check that if input voltage is the same with rated voltage 2 Check grounding cable and...

Page 15: ...9 www BormannTools com...

Page 16: ...10 www BormannTools com...

Page 17: ...11 www BormannTools com...

Reviews: