Fitting - installing:
• The cut out sizes are:
Reference Cut-size
MI-61
560 x 490 mm
Installation instructions
The installation comes under the exclusive res-
ponsibility of specialists.
The installer is held to respect the legislation
and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infil-
tration of liquids in the cabinet.
His installation has to be done carefully, in con-
formity of the following drawing.
Stick the gasket (2) two millimeters from the
external edge of the glass, after removing the
protection sheet (3).
2 mm
• Ensure that there is a distance of 50 mm bet-
ween the hob and the wall or sides.
• The hobs are classified as “Y” class for heat
protection. Ideally the hob should be instal-
led with plenty of space on either side. There
may be a wall at the rear and tall units or a
wall at one side.
On the other side, however,
no unit or divider must stand higher than the
hob.
• The piece of furniture or the support in which
the hob is to be fitted, as well as the edges
of furniture, the laminate coatings and the
glue used to fix them, must be able to resist
temperatures of up to 100 °C.
• The mural rods of edge must be heat-resi-
sting.
• Not to install the hob to the top of a not ven-
tilated oven or a dishwasher.
• To guarantee
under the bottom of the hob ca-
sing a space of 20 mm
to ensure a good air
circulation of the electronic device.
• If a drawer is placed under the work, avoid
to put into this drawer flammable objects
(for example: sprays) or not heat-resistant
objects.
• Materials which are often used to make
worktops expand on contact with water. To
protect the cut out edge, apply a coat of var-
nish or special sealant. Particular care must
be given to applying the adhesive joint sup-
plied with the hob to prevent any leakage into
the supporting furniture. This gasket guaran-
ties a correct seal when used in conjunction
with smooth work top surfaces.
• The safety gap between the hob and the
cooker hood placed above must respect the
indications of the hood manufacturer. In case
of absence of instructions respect a distance
minimum of 760 mm.
• The connection cord should be subjected, af-
ter building, with no mechanical constraint,
such for example of the fact of the drawer.