3
1
Installation of indoor unit
3. Remove the wire clip; connect the power connection wire to the wiring terminal
with wire clip.
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3
2
N(1)
Outdoor unit connection
green
green)
red
black
(yellow-
(brown)
white
(blue)
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
6. Install the Conduit assy.
1) Fix the conduit assy on the conduit board and then let the connection wire
between indoor unit and outdoor unit go through the conduit.
2) Fix the conduit assy on the chassis with 3 screws.
●
Conduit assy consists of conduit, conduit connector and lock nut.(Not the
standard part, which should be purchased by customer.)
●
The length of conduit can be calculated according to the length of connection wire.
Note:
●
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
Lock nut
Conduit connector
Cable Cross Plate
Conduit
connection wire
sleeve