Installation
www.bora.com
Positioning the door
4
Fig. 9.14
Adjusting the distance between the
operating unit and door
X
Ensure that there is an even distance of 4 mm
between the operating unit and the door. To do
this, turn the adjusting screws on the front of the
top of the housing.
Positioning the appliance
X
Push the appliance into the desired position in
the installation recess. Ensure that the water
hoses and mains supply cable are not trapped or
damaged in doing so.
X
Maintain a minimum distance of 30 mm between
the back of the appliance and the adjacent
elements.
X
Position the appliance midway between the
interior walls of the installation recess.
1
2
PE
3
220
–
240 V
~
L1
1
5
L2
2
220
–
240 V
~
N
4
L3
PE
3
220
–
240 V
~
L1
1
5
2
N
4
L2
L3
Fig. 9.13
Connection diagrams
[1]
Connection diagram – two-phase connection, 16 A
[2]
Connection diagram – single-phase connection, 16 A
X
Connect the power supply cable to the power
supply of the appliance in accordance with the
relevant connection diagram (see Fig. “Connection
Diagrams”).
X
Secure the power supply cable with the strain
relief clamp.
X
Close the power supply housing cover.
X
Check that installation has been carried out
correctly.