10
Removing the Bit
1. Unplug the motor from the power source
2. Loosen the collet nut from the collet shaft
using two wrenches.
2. Once loose, unscrew the collet nut by
hand until it feels tight again.
3. Return to using the wrenches until the bit
shank can be pulled out.
Operation
To reduce the risk of injury, wear safety goggles or
glasses with side shields. Always wait for the bit to
stop completely and unplug the tool before changing
accessories or making adjustments. Never make
adjustments while the router is running. Do not modify or
remove the guards.
Do not use this router unless it is securely installed into
a recommended router lift and table.
Variable Speed Dial
The variable speed dial allows you to adjust the rotating speed (RPM) of the tool.
Use the following chart to determine the best speed for the bit diameter.
Speed Setting
RPM
Max. Bit Diameter
Slow
10,000
3” to 3-½”
Slow
12,000
3” to 3-½”
Medium
14,000
2-¼” to 2-½”
Medium
16,000
2-¼” to 2-½”
Medium
18,000
1-¼” to 2”
Fast
20,000
1”
Fast
22,000
1”
Electronic Overload Protection
Before the motor is overloaded, the electronic overload protection circuit will turn
off the tool.