Installation
www.bora.com
Q
Q
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.
Q
Q
The drawers and/or shelves in the floor unit must be
removable for maintenance and cleaning purposes.
X
X
Make sure that the area at the front of the floor unit is
sufficiently ventilated with clean air.
X
X
Make sure that the floor unit is not soiled by the
ventilation openings.
4.9.1 Fitting and positioning the cooktop
extractor
1
2
Fig. 4.22 Insert the cooktop extractor in the worktop cut-out.
[1]
Cooktop extractor
[2]
Worktop cut-out
X
X
Place the cooktop extractor [1] in the middle of the
worktop cut-out [2].
X
X
Position the cooktop extractor [1] with precision.
Adjusting the installation height (only in the
case of flush installation)
Fig. 4.23 Height adjustment plates for flush installation
[1]
Height adjustment plate
[2]
Cooktop extractor
X
X
In flush installation, if necessary, lay height adjustment
plates [1] underneath in order to adapt the installation
height of the cooktop extractor [2] to the rebate depth.
4.10 Installing the duct system
INFO
The duct system must be fitted to the cooktop
extractor free of load and with the power supply
switched off.
INFO
Please bear in mind that for correct installation,
the slide-in units of the base cabinet can be
shortened depending on the installation situation.
INFO
When attaching the seals, ensure that an airtight
seal is created with the connection duct piece
when the seals are compressed.
Q
Q
The maximum exhaust air duct length with a fan is 6 m.
Q
Q
The minimum cross-section of the air ducts must
be 176 cm², which equates to a round pipe with
a diameter of 150 mm or the BORA Ecotube duct
system.
X
X
Use only BORA Ecotube duct parts.
X
X
Do not use flexible or fabric hoses.
4.10.1 Fitting the duct system to cooktop
extractor CKA2
INFO
The floor unit must not be supported on the plinth
fan housing. The plinth fan must be installed free
of load and with the power supply switched off.
INFO
The plinth fan must only be installed horizontally.
INFO
Position the plinth fan and control unit in such
a way that they cannot be easily accessed by
the user under normal operating conditions (e.g.
behind the plinth panel).
Preparations
X
X
Adjust the ducting parts to the height of the worktop.
X
X
Saw out the necessary cut-outs for the ducting in the
rear panel of the floor unit.
X
X
Depending on the installation situation, adjust the
levelling feet on the floor unit as necessary.