![bora Classic CKCB Installation Instructions Manual Download Page 16](http://html1.mh-extra.com/html/bora/classic-ckcb/classic-ckcb_installation-instructions-manual_2788242016.webp)
EN
16
Technical data
www.bora.com
Device dimensions CKG
327
131
240
515
Fig. 3.20 CKG device dimensions top view
246
299
40,5
14
25
73
37
Fig. 3.21 CKG device dimensions front view
487
485
14
15
Fig. 3.22 CKG device dimensions side view
3.7 CKG
Parameter
Value
Supply voltage
220-240 V
Frequency
50/60 Hz
Total burner output
5.0 kW
Power rating
20 W
Fuse protection
1 x 0.5 A
Dimensions (width x depth x height)
cooktop pan support high-power burner
pan support normal burner
327 x 515 x 73 mm
270 x 270 x 25/50 mm
235 x 235 x 25/50 mm
Weight (incl. accessories/packaging)
11.5 kg
Cooktop
Power levels
1 – 9, P
Warming levels
3
High-power front burner
800 – 3000 W
Normal rear burner
550 – 2000 W
Total nominal connection values
G20/20 mbar:
5.00 kW 0.449 m³/h
Cooktop energy consumption G20/20 mbar
Category I2H 20 mbar
(measurement taken without cooktop extractor)
High-power front burner
800 – 3000 W 63.3 %
Normal rear burner
550 – 2000 W 61.3 %
Total (average)
62.3 %
Tab. 3.7 Technical data
Summary of Contents for Classic CKCB