EN
15
Installation
www.bora.com
10
10 ... 40
Abb. 6.5 Surface mounting cut-out
Cut-out dimensions when installing cooktops only or cook-
tops and the BORA cooktop extractor alongside each other:
Cooktops/cooktop extractor
A in mm
B in mm
1/0
344
320
2/0
685
661
3/0
1026
1002
2/1
776
752
3/2
1208
1184
4/2
1549
1525
Tab. 6.2 Cut-out dimensions
Attaching the sealing tape
1
2
Abb. 6.6
Sealing tape with flush installation
[1]
Black, heat-resistant silicone sealant
[2]
Sealing tape
2
1
Abb. 6.7 Sealing tape with surface mounting
[1]
Black, heat-resistant silicone sealant
[2]
Sealing tape
Flush installation
A
B
519
R5
<R5
> 50
495
> 600
Abb. 6.2 Flush installation
5
12
10 ... 40
Abb. 6.3 Groove dimensions cut-out
INFO
If the induction glass ceramic wok is used, the
groove dimensions must be increased to 7 mm
for flush installation.
Surface mounting
B
<R5
> 50
495
> 600
Abb. 6.4 Surface mounting