background image

EN

4

General

www.bora.com

INFO 

BORA Holding GmbH, BORA Vertriebs 

GmbH & Co KG, BORA APAC Pty Ltd and BORA 

Lüftungstechnik GmbH - hereinafter referred 

to as BORA - shall not assume any liability for 

damage caused by non-compliance with these 

documents nor by improper assembly! 

The electricity and gas connections must be 

implemented by a certified engineer. 

Assembly must only take place in compliance 

with the applicable norms, regulations and 

laws. All safety and warning information and 

handling instructions in the operating and 

assembly instructions must be followed.

Validity of the operating and assembly 

instructions

This manual is valid for several versions of the device. For 

this reason, it is possible that individual features are 

described in the manual that do not apply to your device.

Other applicable documents

Additional documents are valid as well as these operating 

and assembly instructions, and likewise need to be obser-

ved.

Please observe all documents included in the scope of 

delivery.

INFO 

BORA cannot assume any liability for damage 

caused by non-compliance with these docu-

ments!

Guidelines

These devices meet the following EC guidelines:

2004/108/EC EMC Directive 

2006/95/EC Low-Voltage Directive 

2009/125/EC Ecological Design Directive 

2011/65/EC RoHS Directive

1  General

Target group

These operating and assembly instructions are intended 

for the following target groups: 

Target group

Requirements

Users

The Device may be used by chil-

dren from the age of 8 as well as 

by people with limited physical, 

sensory or mental capabilities or a 

lack of experience and/or knowl-

edge, provided they are super-

vised, have been instructed in the 

safe use of the device and have 

understood the dangers involved. 

Children must be supervised. All 

safety and warning information 

and handling instructions in the 

operating manual must be fol-

lowed.

Ambitious Diyers

Ambitious Diyers may carry out all 

the necessary carpentry and 

assembly work themselves provi-

ding that they have the necessary 

skills and knowledge. They must 

not connect the current and gas 

themselves.

Assembly 

expert

The assembly expert must carry 

out all the necessary carpentry 

and assembly work taking existing 

regulations into account. The cur-

rent and gas connections must be 

approved for the system in use by 

a certified electrician before use.

Electrical  

expert

The electrical connection must 

only be executed by a certified 

electrician. He/she also assumes 

responsibility for the proper elec-

trical installation and commission-

ing.

Expert  

gas connection

The gas connection must only be 

implemented by a certified gas 

engineer. He/she also assumes 

responsibility for the proper gas 

installation and commissioning.

Tab. 1.1:  Target groups

Summary of Contents for CCH1

Page 1: ...EN CCH1UMEN 000 www bora com Operating and installation instructions CCH1 Hyper glass ceramic cooktop with 2 cooking zones 1034813...

Page 2: ...bH Rosenheimer Str 32 83064 Raubling Germany Contact T 49 0 8035 907 240 F 49 0 8035 907 249 info bora com www bora com Distribution and duplication of this document use and disclosure of its contents...

Page 3: ...nd aids 14 5 3 Assembly instructions 14 5 3 1 Safety distances 14 5 4 Cut out dimensions 15 5 5 Installing the cooktop 16 5 5 1 Installing the cooktop 16 5 6 Power connection 17 5 7 Handover to user 1...

Page 4: ...2011 65 EC RoHS Directive 1 General Target group These operating and assembly instructions are intended for the following target groups Target group Requirements Users The Device may be used by chil d...

Page 5: ...h symbols and signal words Safety and warning instructions are structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Results of non compliance X X Measures to minimise ris...

Page 6: ...leaning agents to prevent scratching and abrasion on the surface X X Make sure that the base of the cookware as well as the cooking zone are clean and dry X X Always lift do not drag the cookware to p...

Page 7: ...ety instructions assembly Installation and assembly of the device may only be carried out by trained personnel who are familiar with and comply with common national regulations and supplementary regul...

Page 8: ...rical safety of the device is only guaranteed if it is connected to a properly installed protective conductor system Make sure that these basic safety precautions have been taken Cooktop DANGER Danger...

Page 9: ...mote control system Not using the device as described in this operating and assembly manual is considered not using the device as intended as is using it beyond the purpose described here BORA shall n...

Page 10: ...340 x 515 x 44 mm Weight incl accessories packaging 6 3 kg Cooktop Power levels 1 9 HY 1 ring front cooking zone 150 mm 1200 W 1 ring back cooking zone with hyper stage 215mm 2100 W 3000 W Cooktop en...

Page 11: ...ted timer 11 Cooking zone indicator 12 Timer button 4 Device description Observe all safety and warning information during operation see the Safety chapter The cooktop has the following features Q Q A...

Page 12: ...his function enables the cooking zone to work at full power for a certain duration after switching on After this time the power level is automatically switched back to the power level set Power level...

Page 13: ...conds the cooktop will switch off X X Remove the finger or object from the cooktop X X Clean the cooktop as required X X Where necessary switch the cooktop back on 4 3 4 Heat retention level The heat...

Page 14: ...e of the worktops and the wall sealing strip must be made of a heat resistant material up to approx 90 C INFO Countertop cut outs must be moisture sealed using suitable means where necessary fitted wi...

Page 15: ...tractor A in mm B in mm 1 0 344 320 2 0 685 661 3 0 1026 1002 2 1 776 752 3 2 1208 1184 4 2 1549 1525 Tab 5 2 Cut out dimensions 5 4 Cut out dimensions Preparing the worktop X X Create the worktop cut...

Page 16: ...ooktop extractor 2 already installed in the centre INFO The cooktop 1 rests on the lateral bar of the cooktop extractor 2 and is thereby stabilised Attaching the sealing tape 1 2 Fig 5 6 Sealing tape...

Page 17: ...iagram X X Verify that the installation was done correctly X X Switch on the main switch automatic circuit breaker X X Put the cooktop extractor into operation see the Operation chapter X X Check all...

Page 18: ...tomatically be taken over Switching off the automatic heat up function The activated automatic heat up function will end prematurely if you X X press the on the cooking zone X X activate the power set...

Page 19: ...X X activate the heat retention level V X X switch off the cooktop with the button 6 1 9 Heat retention level Q Q A cooking zone is in operation Q Q The power level 1 is activated X X Press to set the...

Page 20: ...r buttons for the front and back cooking zone at the same time Then press the sensor button for the front cooking zone again Q Q Both cooking zone indicators will display L The child safety lock is ac...

Page 21: ...ns crumbs or similar which fall onto the cooktop during general cooking work right away to prevent the surface from being scratched Coloured changes and shiny surfaces are not cooktop damage They do n...

Page 22: ...cooking zone indicator The child safety lock is activated Switch off the childproofing feature see Operation chapter is displayed in the cooking zone indicator Press and hold one or more buttons Clean...

Page 23: ...way Disposal of transport packaging INFO The packaging protects the device against transport damages The packaging is made of materials that are environmentally friendly and easy to dispose of and can...

Page 24: ...7 X X In the case of faults you cannot fix yourself contact your BORA specialist supplier or BORA After Sales Service The After Sales Service will require the type designation and the serial number of...

Page 25: ...EN 25 Notes www bora com EN 11 Notes...

Page 26: ...EN 26 Notes www bora com...

Page 27: ......

Page 28: ...0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com...