9
Battery selection
IMPORTANT - DO NOT MIX BATTERY CHEMISTRY WHEN USING
Wallaby Switch. ALWAYS USE BATTERIES OF THE SAME CHEMIS-
TRY AND CAPACITY.
Wallaby Switch comes pre-calibrated to monitor voltage levels and
current consumption of
LiFeP04
chemistry batteries. I
f you are
using LiPo or Lion batteries you will need to re-calibrate Wallaby
Switch
. Wallaby Switch is easy to calibrate.
How To Calibrate - connect both batteries to Wallaby Switch
and wait until the system check is complete (three slow flashes).
Press and hold
the
RED “ENTER” button.
After a brief period the
LED will start to flash rapidly. While rapidly flashing, release the
RED “ENTER” button.
Depending on currently selected battery
chemistry the LED will then flash as follows:
LiFe monitoring
Three flashes - pause - three flashes etc
Lion and Lipo
One flash - pause - one flash etc
Pressing the
RED “ENTER” button
or
GREEN “ON/OFF”
will cycle
through the different battery types. Once you have selected the
battery type to match your batteries just release the button.
Wallaby Switch will automatically return back to normal mode
after 4 flash cycles.