background image

 

Page 22 

3BE390845NI – 01/12 

 

 

BONNET GRANDE CUISINE 
Registered office: 
Rue des Frères Lumière - Z.I Mitry Compans 
F-77292 MITRY MORY Cedex

 

 

 

65 dm

BRATT PAN 

 

 

GAS 

JETS 

 

Designation 

Pressure 

Burner 

No.  Diameter 

Code 

 

Family 

Type 

(mbar) 

type 

 

(1/100th)  (mm) 

 

Burner 

Natural 

G 20 / G 25 

20 / 25 

BP 

165 

311 131-165 

 

Gas 

 

 

BS G/D 

195/175 

7/5 

311 131-195/175 

 

 

G 25 

20 

BP  

185 

311 131-185 

 

 

 

 

BS G/D 

220/195 

7/5 

311 131-220/195 

 

 

G 25*** 

25 

BP  

170 

311 131-170 

 

 

 

 

BS G/D 

205/185 

7/5 

311 131-205/185 

 

L.P.G 

G 30 

28-30 

BP  

100 

7.5 

311 131-100 

 

 

 

 

BS G/D 

115/105  9/7.5  311 131-115/105 

 

 

G 31 

30 or 37 

BP  

110 

311 131-110 

 

 

 

 

BS G/D 

125/110 

9/7 

311 131-125/110 

 

 

G 30 or G 31* 

50 

BP 

95 

6.5 

311 131-95 

 

 

 

 

BS G/D 

105/100  9/6.5  311 131-105/100 

 

 

G 31** 

50 

BP 

100 

311 131-100 

 

 

 

 

BS G/D 

120/110 

8/6 

311 131-120/110 

Pilot 

Natural 

G 20 / G 25 

20 / 25 

41 

310 273 

 

Gas 

G 25 

20 

45 

311 172 

 

L.P.G 

G 30 or G 31 

28-30 or 37 

25 

310 274 

 

 

G 30 or G 31 

50 

25 

310 274 

BSG: Left hand secondary burner   BSD: Right hand secondary burner 
* Configuration valid only for propane 50 mbar in Austria 
** Configuration not permitted in Austria                                 *** Configuration valid only in Netherlands. 

 

 
 
 
RA: Air adjustment 
 

  Air adjustment sleeve must be set to the 

 

dimensions given for “d“ above. 

 

 

 

 

 

 
 
Pilot air adjustment
 (Valid for all models) 
 

 Airflow can be adjusted using the collar that 

 

obstructs 1 of the two primary air holes.  

 
 

 

 

Collar 

Summary of Contents for B1A9S+50EBE

Page 1: ... approved personnel and in compliance with current standards and regulations Anyone modifying this equipment assumes complete responsibility for it These units should only be used in a well ventilated environment Read these instructions carefully before installation It is vital that these units remain on their pallets whilst being moved and until they are in their final location 3BE390845NI ...

Page 2: ...BLING UNITS CANTILEVERED OFF A WALL 7 3 1 1 FREE STANDING UNITS 7 3 1 2 CANTILEVERED 9 3 2 ASSEMBLING UNITS ON INDIVIDUAL LEGS 11 3 3 ASSEMBLING UNITS ON A CONCRETE PLINTH 12 4 INSTALLATION CONNECTIONS 14 4 1 ELECTRICAL CONNECTION 14 4 1 1 GAS BRATT PANS 14 4 1 2 ELECTRIC BRATT PANS 15 4 2 GAS CONNECTION 16 4 3 WATER CONNECTION 17 5 CHANGING FROM ONE TYPE OF GAS TO ANOTHER 18 5 1 LIST OF AUTHORISE...

Page 3: ... 6 4 09 4 09 1017 1600 680 B1A9SA45EBG 900 Bratt Pan 45dm Elec Tilt Gas 230 a c 0 30 1 30 16 70 1 59 0 0 1 62 2 17 2 46 2 46 1017 800 1014 B1A9SA45EBG 900 Bratt Pan 45dm Elec Tilt Gas 230 a c 0 30 1 30 20 50 1 59 0 0 1 62 2 17 2 46 2 46 1017 800 1014 B1A9SA45MBE 900 Bratt Pan 45dm Manual Tilt Elec 230 3a c 13 50 33 90 0 00 0 0 0 0 0 0 0 1017 800 1014 B1A9SA45MBE 900 Bratt Pan 45dm Manual Tilt Elec...

Page 4: ...In any correspondence about your equipment please indicate The model number Model The serial number Fab Nr The date Date Data plate Gas setting plate The box marked with a cross indicates the gas for which the appliance has been adjusted A second adjacent plate indicates The gas that the unit is set up for The intended destination Country of destination Advancia bratt pan Advancia Plus bratt pan L...

Page 5: ...appliance is installed NOTE Both the gas and pressure for which the appliance is set must be authorised in the country in question Check this point in the section Changing the appliance from one gas to another 1 2 ELECTRIC BRATT PAN The data plate is stuck to the upper part of the control panel see diagram below In any correspondence about your equipment please indicate The model number Model The ...

Page 6: ...and any local and national regulations in force relating to water These units should only be placed against a wall or a partition This must be of non combustible materials or if not must be covered with an appropriate good insulating and non combustible material The manufacturer certifies that the packaging meets the provision 94 62 CE relating to packaging and packaging waste of 20 12 94 and requ...

Page 7: ...ixing brackets must be able to support a force of 4000 N m 2 brackets for units that are 400 600 800 1000 1200 or 1400 wide It is advisable when cantilevering equipment off a concrete wall to comply with the following points The reinforced concrete should be of at least 30 N mm2 C20 25 standard Use HSA R M 8 x 75mm rawlbolts or equivalent 2 for cooking tops and 6 for ranges For the rawlbolts menti...

Page 8: ... the top holes Service runs wall reinforcing use the bottom holes Remove the template Enlarge the fixing bracket holes to 8mm and to a depth of at least 65mm Bolt the fixing brackets to the wall Use HSA R M 8 x 75mm rawlbolts or equivalent Open the brackets to their maximum using the central screw Bracket open Opening screw Position the units on the brackets and tighten the brackets fully Note The...

Page 9: ...sides of the flue vents using 5 x 16mm setscrews and 5mm washers 3 1 2 CANTILEVERED Procedure The wall brackets must be solidly fixed to the wall in the positions indicated below Wall support anchorage point table 1200 wide 1400 wide 1600 wide A 1200 1400 1600 C 1120 1320 1520 The fixing brackets must be able to support a force of 4000 N m 2 brackets for units that are 1200 to 1600 ...

Page 10: ... the minimum distance between the rawl bolt hole and a side wall or corner is 95mm Hook the first unit onto its supports Flatten it against the wall using the adjuster screw in the bracket Adjust the height 900mm and level right to left using the top adjuster Level front to back with the lower adjuster Tighten the nuts and the lock nuts Fit the other units in the same way Fix adjacent units togeth...

Page 11: ...SINE Registered office Rue des Frères Lumière Z I Mitry Compans F 77292 MITRY MORY Cedex 3 2 ASSEMBLING UNITS ON INDIVIDUAL LEGS Fix adjacent units together at the rear through the sides of the flue vents using 5 x 16mm setscrews and 5mm washers ...

Page 12: ...e Full tiled base 1 cm m maximum slope 1 cm m maximum slope 1 cm m maximum slope Finished height with tiled front Finished height with tiled front Plinth dimensions Range Am Depth of wall plinth Ac Depth of central plinth Ls Plinth length Finished height tiled to front Advancia 710 1420 Lf 50 110 A technical compartment is required if the stop cock isolator or gas regulator is to be located in the...

Page 13: ... the front edges in both cases using HM5 X 16 bolts 5mm Ø washer and nut Make all the necessary gas water and drainage connections Fit the plinth trims One espace 2000 front trim per unit and a left and right hand trim according to the order Assemble the trim s with 2 screws per junction in accordance with the number of legs Fix the front trim s and onto the legs at least two screws per trim Fit t...

Page 14: ...e of model Undo the screw holding the terminal strip support plate Tilt to the left Thread the cable through the gland Tighten the gland Connect the wires Refit the plate Connect the earth cross bonding to the terminal provided Only use H07 RN F type supply cable 3 x 2 5mm2 section A local isolator must be provided for fixed supply wiring All aspects of the installation should be in compliance wit...

Page 15: ...o the terminal provided Only use H07 RN F type supply cable sized to suit the load of the unit as defined in the table below see chapter 1 technical characteristics which give the electrical rating Intensity A Cable section mm 0 1 to 16 2 5 16 to 25 4 25 to 40 6 40 to 63 10 63 to 96 16 A local isolator must be provided for fixed supply wiring All aspects of the installation should be in compliance...

Page 16: ...and the total load of the unit To check the gas pressure connect a water gauge to the test point on the gas control unit point A on the diagram below The measured dynamic pressure should be the same as that indicated on the gas data plate for the gas in question See paragraph 1 Advancia bratt pan Advancia Plus bratt pan TEST POINT A Slacken the screw without removing it Connect the water gauge pip...

Page 17: ...tt pan Advancia Plus type bratt pan Cold water Hot water Cold water Hot water Advancia Plus cantilevered bratt pan Cold water Hot water Water supply pipe purging A purge has been added to the water delivery this automatically purges the pipe work after the well is filled This purging produces a trickle of water from below the front of the unit which runs into the floor gulley If this is undesirabl...

Page 18: ...20 II2H3B P G 30 and G 31 50 Sweden Denmark I2H G 20 20 Finland I3B P G 30 G 31 30 Belgium G 20 G 25 20 25 II 2E 3P G 31 37 I3 G 30 G 31 28 30 37 Germany G 20 G 25 20 II2ELL3B P G 30 G 31 50 I3P G 31 50 Ireland United Kingdom G 20 20 Greece Switzerland II2H3P G 31 37 Portugal I3 G 30 G 31 28 30 37 Italy I2H G 20 20 I3 G 30 G 31 28 30 37 Spain G 20 20 II2H3P G 31 37 or 50 I3B P G 30 G 31 30 France ...

Page 19: ...quire 2 operations CI Change jets main burner pilot See paragraph 5 4 RA Adjustment of primary air See paragraph 5 4 PROCEDURE On the data plate check The category ies of the equipment The gas and pressure for which it is adjusted In the following table select the country in question the gas and the category of the equipment see above the gas and pressure for which the equipment is going to be set...

Page 20: ...G 31 37 I3 CI RA Spain G 20 20 G 31 37 50 CI RA G 31 37 G 31 50 II2H3P CI RA G 30 30 G 31 30 I3B P None France G 20 or G 25 20 25 G 30 or G 31 50 CI RA G 20 20 G 25 25 None G 30 50 G 31 50 II2E 3B P None G 20 or G 25 20 25 G 31 37 50 CI RA G 31 37 G 31 50 II2E 3P CI RA G 30 28 30 G 31 37 I3 CI RA G 20 20 G 30 or G 31 50 CI RA G 30 50 G 31 50 II2E3B P None Luxemburg G 20 20 G 31 50 II2E3P CI RA G 3...

Page 21: ...5 20 25 1 41 310 273 Gas G 25 20 1 45 311 172 L P G G 30 or G 31 28 30 or 37 1 25 310 274 G 30 or G 31 50 1 25 310 274 50 dm2 BRATT PAN GAS JETS Designation Pressure Burner No Diameter d Code Family Type mbar type 1 100th mm Burner Natural G 20 G 25 20 25 BP 4 165 5 311 131 165 Gas BS 1 195 7 311 131 195 G 25 20 BP 4 185 5 311 131 185 BS 1 220 7 311 131 220 G 25 25 BP 4 170 5 311 131 170 BS 1 205 ...

Page 22: ...P 4 110 7 311 131 110 BS G D 2 125 110 9 7 311 131 125 110 G 30 or G 31 50 BP 4 95 6 5 311 131 95 BS G D 2 105 100 9 6 5 311 131 105 100 G 31 50 BP 4 100 6 311 131 100 BS G D 2 120 110 8 6 311 131 120 110 Pilot Natural G 20 G 25 20 25 1 41 310 273 Gas G 25 20 1 45 311 172 L P G G 30 or G 31 28 30 or 37 1 25 310 274 G 30 or G 31 50 1 25 310 274 BSG Left hand secondary burner BSD Right hand secondar...

Page 23: ...25 20 25 1 41 310 273 Gas G 25 20 1 45 311 172 L P G G 30 or G 31 28 30 or 37 1 25 310 274 G 30 or G 31 50 1 25 310 274 75 dm2 BRATT PAN GAS JETS Designation Pressure Burner No Diameter d Code Family Type mbar type 1 100th mm Burner Natural G 20 G 25 20 25 BP 5 165 5 311 131 165 Gas BS 2 195 7 311 131 195 G 25 20 BP 5 185 5 311 131 185 BS 2 220 7 311 131 220 G 25 25 BP 5 170 5 311 131 170 BS 2 205...

Page 24: ...res Lumière Z I Mitry Compans F 77292 MITRY MORY Cedex RA Air adjustment Air adjustment sleeve must be set to the dimensions given for d above Pilot air adjustment Valid for all models Airflow can be adjusted using the collar that obstructs 1 of the two primary air holes Collar ...

Reviews: