4.2 GAS CONNECTION
Check that the unit is set to the type and pressure of gas provided on site. (See paragraph 1: Data
plate).
Connect the unit to the main gas float via a stop cock to allow the unit to be individually isolated.
The gas supply line should be sized to minimise pressure drop, its diameter is a function of its route, length
number of bends and the total load of the unit.
To check the gas pressure connect a water gauge to the test point on the gas control unit (point A on
the diagram below).
The measured dynamic pressure should be the same as that indicated on the gas data plate for the gas
in question (See paragraph 1)
Advancia bratt pan
Advancia Plus bratt pan
TEST POINT A:
Slacken the screw (without
removing it)
Connect the water gauge pipe.
Take measurement with the
burners on.
Gas connections must meet current regulations (DTU 61.1) and be carried out only by qualified
registered installers.
Final connections are to a ½” male gas connection.
Advancia type bratt pan
Advancia Plus type bratt pan
Gas connection
Gas connection