8
6. Optional setting
MW50 has various functions. Please use the function with your convenience.
(A) Alarm function Upper limit setting
①
Set the upper limit alarm of soldering temperature
Initial setting: 50
℃
Ⅰ:
At the operation mode, press
key with pressing
△
key.
is indicated at PV screen.
Ⅱ:
Push
key 5 times,
is indicated at PV screen.
Ⅲ:
Input the value by
△
or
▽
key at SV screen. Push
key 2 times to return to operation mode.
Operation mode
⇒
AT setting screen
⇒
Upper limit alarm function
⇒
Operation mode
あ
Upper limit alarm: It alarms when the temperature exceed the range
○○℃
of setting temperature.
Example:
The upper limit is set as 50. setting temperature is
350
℃
.
It alarms when temperature become over
400
℃
.
Set 0 when alarm function is unnecessary.
(B) Alarm function Lower limit setting
①
Set the lower limit alarm of soldering temperature
Initial setting
:-
50
℃
Ⅰ:
At the operation mode, press
key with pressing
△
key.
is indicated at PV screen.
Ⅱ:
Push
key 6 times,
is indicated at PV screen.
Ⅲ:
Input the value by
△▽
key at SV screen. Push
key once to return to operation mode.
Operation mode
⇒
AT Setting Screen
⇒
lower limit alarm function
⇒
Operation mode
あ
Lower limit alarm: It alarms when the temperature exceed the range
○○℃
of setting temperature.
Example:
The lower limit is set as
-
50. setting temperature is
350
℃
.
It alarms when temperature become under
300
℃
.
Set 0 when alarm function is unnecessary.