User’s Manual
13
3. I
NSTALLATION
I
NSTRUCTIONS
3.1.
E
NVIRONMENT
While closed, the M3628PCF is water, dust, and crush resistant. When open and in
operation, the unit should be used only in dry, clean areas. Ensure that the interior of
the unit casing is kept dry.
3.2.
W
IRING AND
C
USTOMER
C
ONNECTIONS
3.2.1.
P
OWER
W
IRING
The power input connector accepts 120VAC or 240VAC 50-60 Hz from the
included standard C13 power cable. The input voltage must be selected
when ordering, and cannot be changed in the field.
The DC output connectors supply DC voltage at the user-selected level via a
pair of banana connectors. Output lead can be constructed as needed.
3.2.2.
S
OURCE
C
ONSIDERATIONS
A three wire source with ground and neutral conductor is required for proper
operation.
Input voltage should not exceed the specified input voltage damage to the
unit may result. The source must be capable of supplying at least 1000VA to
guarantee correct system operation at all output voltages.
CAUTION!
Always use a three wire connection with a bonded neutral conductor.
A floating or ungrounded source may result in incorrect readings on the
voltmeters.
Summary of Contents for M3628PCF
Page 6: ...M3628PCF 6 This page intentionally left blank ...
Page 14: ...M3628PCF 14 This page intentionally left blank ...
Page 22: ...M3628PCF 22 This page intentionally left blank ...
Page 25: ...User s Manual 25 Figure 7 2 Rockwell Automation Part 2 ...
Page 26: ...M3628PCF 26 Figure 7 3 ABB ACS 800 Part 1 ...
Page 27: ...User s Manual 27 Figure 7 4 ABB ACS 800 Part 2 Figure 7 5 Schneider ATV61 71 ...
Page 28: ...M3628PCF 28 Figure 7 6 Siemens Micromaster 440 ...
Page 29: ...User s Manual 29 NOTES ...
Page 30: ......
Page 31: ...Web www bonitron com Tel 615 244 2825 Email info bonitron com ...